DS1784-001
3.3.5 Default settings
All default door unit settings are:
Function Default Corresponding DIP switch
Station type Main (OFF) SW4 DIP switch 1
Secondary calling station address 0 (OFF) SW4 DIP switch 2
Door opener
Private (OFF) SW4 DIP switch 3
Interruption Not enabled (OFF) SW4 DIP switch 4
Camera LED on Function ON SW4 DIP switch 5
Number of users
One-family (OFF) 1784/1
Two-family (ON) 1784/2
SW4 DIP switch 6
Door unit number (ID) 0 (all OFF) SW3 DIP switch 1 ÷ 5
Door opening time 1 sec (OFF - OFF) SW2 DIP switch 1 - 2
Auto-on restriction with even ID code
Function OFF SW2 DIP switch 3
Call address button management 0 (OFF) SW2 DIP switch 4
DOOR STATUS or LETTERBOX function Door status (OFF) SW2 DIP switch 5
50/60 Hz camera 50 Hz (OFF) SW2 DIP switch 6
Guaranteed communication time rotary 30 seconds (pos 3) SW1 Rotary switch
Default con guration Ref. 1784/1
SW2
SW3
SW4
SW1
Default con guration Ref. 1784/2
SW2
SW3
SW4
SW1
3.3.6 Speaker volume adjustment
Volumes are calibrated by default so not to require adjustments in most cases.
Use a screwdriver to adjust the speaker volume, if required (See COMPONENT DESCRIPTION paragraph).
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Urmet MIKRA 2 VT 1784-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Urmet MIKRA 2 VT 1784-1 in the language / languages: English, German, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 8,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info