UNO
X
R
ENGLISH
ENGLISH
14
BREAKDOWN CAUSE SOLUTION
The tension of the electrical
system is missing
Restore the tension
Safety thermostat intervention Refit the safety thermostat
Intervention of one of the fuse
of the power board
Replacement of the fuse
The oven is completely turned
off
The connection to the electrical
system not made in the correct
way
Control the connection of the
appliance to the electrical
system
The water inlet is closed Open the water inlet
The connection to the water
system or to the external tank
not made in the proper way
Control the connection to the
water system or to the external
tank
No water in the external tank
(in case the oven is connected
to an external tank)
Pour water into the tank
The inflow of humidity in the
cavity is on, but the water does
not come out of the pipes
The filter on the water
connection is closed by dirt
Clean the filter
The door is open or it is not
properly closed
Close the door in the correct
way
The oven does not start even
though you set the time and
pressed the START/STOP key
Damaged door micro switch Contact a specialized
technician for reparation
The wires that connect the
avity probe are not connected
o the power board
c
t
Control the connections
On the temperature display
you can read EE1
Damaged cavità probe Contact a specialized
technician for reparation
Damaged door basket Contact a specialized
technician for reparation
There is water coming out of
the cavity from the door
basket, even though the door
is closed
Loosened door mechanism Contact a specialized
technician for reparation
Burnt lamp Sostituire la lampadina
The oven light does not turn on
Loosened lamp Inserire in maniera corretta la
lampadina nel portalampade
The fans do not reverse the
rotating direction
Contact a specialized
technician for reparation
One of the fans do not work (in
case that you have an oven
with more than one motor)
Contact a specialized
technician for reparation
The cooking results are even
One of the heating element is
broken
Contact a specialized
technician for reparation
3. MORE FREQUENT BREAKDOWNS
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Unox XF138-TG Dynamic at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Unox XF138-TG Dynamic in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 1,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info