778984
8
Zoom out
Zoom in
Previous page
1/33
Next page
Remove the lter cover.
The lter should be rinsed with water, e.g. from
a garden hose, and it can be re-installed in the
device. If the lter is discoloured or has dirt that
cannot be removed, replace it with a new one.
Put the cover on the lter.
Screw the lter to the pool wall.
Draining the water
Disconnect the device from the power supply.
Make sure that the hole in the oor on the inside
of the pool is closed.
Open the water outlet on the outside of the pool.
Connect one end of the hose.
Open the hole plug on the inside of the pool, the
water will ow out through the hose.
3.3. DEVICE USE
Powering the device
The device is equipped with a power cord with
a residual-current device (circuit breaker). The circuit
breaker should be tested regularly. For this purpose,
reset the switch by pressing the Reset button. Start any
of the jacuzzi functions, e.g. air bubbles, and then press
the TEST button. The switch should cut o the power
supply from the device. Press the RESET button again to
return to the normal operating mode.
PLEASE NOTE: If, after pressing the TEST button, the
switch does not cut o the power supply from the
device, immediately stop using the jacuzzi and contact
the manufacturer‘s service department.
Water ltration function
Press the ltration On/O button. The device will
begin to lter, the diode will light on the button.
Pressing the ltration On/O button again will
turn o the ltering process, the LED on the
button will go o.
When the lter pump runtime exceeds 168 hours,
„FC“ will appear on the display and a signal will
be displayed. This will be information about the
need to replace or clean the lter. The LED on the
lter button will be lit, but the ltering itself will
be turned o. Other device systems will also not
work. To turn o the message, press the ltration
On/O button, the current water temperature
will appear on the display. To restore the ltration
system activity, replace or clean the lter.
Massage function with air bubbles
Press the On/O button for the air bubbles. The
device will start to spray air into the water in front
of the nozzles, the diode will light on the button.
Do not activate the function if a cover is placed
on the pool.
Pressing the bubbles On/O button again will
turn o the bubble release process, the LED on
the button will go o.
The nozzle system automatically stops working
after 20 minutes. To restart the function, wait 10
minutes.
For the rst 15 minutes of the function it can be
turned o and turned on without interruption.
After the time of 15 minutes has elapsed after
switching o the air bubble function, wait 10
minutes before turning it on again.
Water heating function
Press the On/O button to heat the water. The
device will start to heat up the water, the diode
will light on the button. It will also light up the
diode on the ltering On/O button. The device
will also start ltering the water.
After reaching the set temperature (temperature
setting is described in the next section), the
device will automatically switch o the heating
and ltration of water. The LEDs on the buttons
will go o.
When the water temperature drops 2°C below the
set value, the heating system and ltration will
start working again.
Pressing the On/O button again switches o the
water heating process, the LED on the button will
go o.
Setting the water temperature
Press the entry button to set the temperature, the
display will ash.
Use the buttons to increase or decrease the
temperature value to set the preferred value.
Press the input button again to set the
temperature to conrm the entered value.
1. The water heating process depends on
the initial water temperature and external
conditions and it takes around 12-24h.
For a water with temperature of 15°C (tap
water), in ideal conditions, heating time will
take 15h to increase the water temperature
up to 30°C.
2. The heater is mainly used to maintain the
water temperature, we recommend lling
the jacuzzi with warm water.
3. The product with clear signs of use, water or
dirt residues is not subject to return.
After draining all the water, activate the air
bubbles release function for about 2-3 minutes to
get rid of water from the tubes in the device.
When nished, disconnect the hose and close the
holes with the plugs.
Storage
Completely drain the pool water. Remove the
lter.
After draining the water, dry the pool with a dry
cloth and leave it to dry for 24 hours until it is
completely dry.
Release the air from the pool by opening the
outlet and air valve, then fold it into the box.
Using the repair kit
If the product gets torn or breaks, use the
provided repair kit.
Clean and dry the area of damage. Cut out the
patch.
Apply the adhesive to the patch, then gently
fasten it to the damaged area.
Smooth the surface to remove air bubbles.
3.4. CLEANING AND MAINTENANCE
a) Before each cleaning, adjustment, replacement
of accessories and if the device is not used, it is
necessary to pull out the mains plug.
b) Use cleaners without corrosive substances to clean
each surface.
c) Contaminants may be deposited on the walls of the
pool. To clean them, use a mild soap and water.
d) After cleaning the device, all parts should be dried
before reusing it.
e) Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
f) Regular inspections of the device must be carried out
in terms of its technical eciency and any damages.
g) Use a soft cloth for cleaning.
Keeping water clean
In order to keep the device in good condition and
not to expose yourself and other users to health
problems, you should regularly clean the water in
the pool.
Water should be periodically cleaned with
chemicals or replaced with fresh water. It is
forbidden to use chemicals with calcium ions.
When using chemicals, follow the
manufacturer‘s recommendations and
instructions for use, and consult with local
authorities regarding the permissible use of these
products
Replace and clean the lter regularly. It is
recommended to clean the lter after every 72-
120 h of use. The lter should be replaced once
a month depending on the intensity of use.
The pH of the water should be maintained at 7.2-
7.8, total alkalinity between 80 and 120 ppm, free
chlorine between 3 and 5 ppm. It is recommended
to use special tests to check the water status.
Tests should be used in accordance with the
recommendations and instructions of their
manufacturer.
Cleaning the lter
Disconnect the device from the power supply
Unscrew the lter from the pool wall.
EN 1514 EN
18.01.2022
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Uniprodo Uni Pools 17 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Uniprodo Uni Pools 17 in the language / languages: English, German, Dutch, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 1.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info