System Settings
3.5.10.1 Connectivity Check
A regular check ensures that the TLS link to the main SIP server is active. When
the Connectivity check timer is set to a non-zero value, test messages will be
sent at the defined interval. If the link is found to be dead, the phone uses DNS
SRV to find another SIP server. Certainly, the DNS SRV records must be properly
configured in the DNS server.
Value range: 0 (off), and 10 to 3600 sec.
If no other primary SIP server is found via DNS SRV, the phone will switch over
to a backup server for making receiving calls. For configuring the backup server,
please refer to Backup SIP Server.
Administration via WBM
System > SIP interface
Related Topics
Related Topics
Resilience and Survivability
3.5.10.2 Response Timer
The Response Timer resp. Call trans. timer is started whenever the phone
sends a new INVITE message to the SIP server.
If the call transaction timer expires before the phone gets a response from the SIP
server, the phone assumes that the server had died and then attempts to contact
the backup server, if configured. If there is no backup server configured, the
phone just tidies up internally.
The data is given in milliseconds. The default value is 32 000; for OpenScape
Voice, the recommended setting is 3.7 seconds (3700 ms).
114


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Unify OpenScape Desk Phone IP V3R3 - Phone Administration SIP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Unify OpenScape Desk Phone IP V3R3 - Phone Administration SIP in the language / languages: English as an attachment in your email.

The manual is 4,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info