647725
90
Zoom out
Zoom in
Previous page
1/104
Next page
82
System Type TGID Format
Motorola Type 2
Systems
N = Decimal Number
H = Hexadecimal Number
i = I-Call ID
Decimal Format
NNNNN
iNNNNN
Hexadecimal Format
HHHH
iHHHH
P25 Systems N = Decimal Number
H = Hexadecimal Number
i = I-Call ID
Decimal Format
NNNNN
iNNNNNNNN
Hexadecimal Format
HHHH
iHHHHHH
EDACS Systems A = Agency
F = Fleet
S = Sub-Fleet
N = Decimal Number
i = I-Call ID
Only AFS Format is allowed for
direct entry except for I-Call ID.
AFS Format
AA-FFS (Normal ID)
AA-FF- (Partial Fleet ID)
AA- (Partial Agency ID)
Decimal Format
NNNN
iNNNNN
LTR Systems A = Area number
RR = Home Repeater Number
U = Decimal Number
A-RR-UUU (Normal ID)
A-RR (Partial Repeater ID
Note: A-RR (Partial Repeater ID) cannot be used with decimal formats.
TYPE II SPECIAL STATUS BITS
Type II Motorola Smartnet systems use these status bits for special transmissions such as
emergency, patches, DES/DVP scrambled transmissions, and multiselects. Motorola trunking
radios directly interpret them for their special functions, thus no difference is noticed by the person
with the radio. The scanner however interprets these special talk group status bits as different talk
groups entirely. Below is the conversion chart for these special status bits.
TT ID + # Usage TT ID + # Usage
ID+0 Normal Talk group ID+8 DES/DVP Encryption talk group
ID+1 All Talk group ID+9 DES All Talk group
ID+2 Emergency ID+10 DES Emergency
ID+3 Talk group patch to another ID+11 DES Talk group patch
ID+4 Emergency Patch ID+12 DES Emergency Patch
ID+5 Emergency multi-group ID+13 DES Emergency multi-group
ID+6 unassigned ID+14 unassigned
ID+7 Multi-select (initiated by dispatcher) ID+15 Multi-select DES TG
Therefore, if a user was transmitting a multi-select call on talk group 1808, the scanner would
actually receive those transmissions on 1815.
Some common uses of these status bits are as follows:
When a user hits their emergency button, all conversations on the talk group revert to
the emergency status talk group (ID+2) until the dispatch clears the emergency status.
90


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Uniden BCD536HP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Uniden BCD536HP in the language / languages: English as an attachment in your email.

The manual is 7,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info