Set Priority – Sets the Priority mode. You can also toggle these modes by holding on any channel
in scan mode and pressing Func then ./no(Pri).
Off - The Priority feature is off.
Priority DND - The scanner checks Priority channels only when not receiving other
conventional channels.
PRI appears in the display reversed -
.
Priority Scan - The scanner checks conventional priority channels.
PRI appears in the display -
.
Set Interval – This sets (in seconds) how often the scanner will check the priority channels.
1-10 sec.
MaxChannels/Pri-Scan – This sets the maximum number of priority channels that are scanned
during one priority scan interrupt. If there are more priority channels than the value you select,
the channels are divided into more than one group and the scanner scans each group in turn.
Example: If you set the maximum channels to 20 and there are 100 priority channels, the scanner
checks those 100 channels in groups of 20 and takes a total of 5 intervals to complete the priority
scan.
1-100
SCANNING BY ASSIGNING QUICK KEYS
With previous scanners, you selected banks to scan. With this scanner, you select Favorites List
and Systems to scan by assigning Quick Keys to them.
See also Understanding Quick Keys.
Scanning is performed with a mixture of FLQK order and SQK order. The scanner will not scan all
Systems in one Favorites List and then move to the next List.
For each Favorites List, starting with 0, the scanner will scan each 0 SQK in FLQK order and then
move to the next set of SQKs for each list.
Example:
FLQK 0, SQK 0; FLQK 1, SQK 0…. FLQK 98, SQK 99; FLQK 99, SQK, 99.
Systems with the same quick key are scanned in order of creation.
The Database is scanned next, in order of creation. Then, Systems with no quick key (including
created Quick Save Systems) are scanned and in order of creation.
Conventional Channels and Departments within Systems are also scanned in order of creation.
IDs are not really scanned. The scanner checks for any activity in the trunking system and:
Will display all IDs when ID Search mode is set to On.
Will display only programmed IDs when ID Search mode is set to Off.
Next, any Custom Searches (enabled for Search with Scan) are scanned in order.
Then, the scanner scans the Close Call ‘Hits with Scan’ system (if Unavoided). This is a system
that automatically stores the frequencies found by Close Call. If the ‘Hits with Scan’ system has no
frequencies, the scanner will not scan the system.
The scanner scans a system for the duration you set using the System Hold Time option. For
trunked systems, the scanner moves to the next system after the hold time expires, the current
transmission ends, and the channel delay expires. Conventional systems operate similarly, but all
(Unavoided) channels are scanned at least one time regardless of the hold time setting.
59


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Uniden BCD536HP at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Uniden BCD536HP in the language / languages: English as an attachment in your email.

The manual is 7,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info