Instructions for the installer
3.27 - BURNER ADJUSTMENT
WARNING!
All the instructions indicated below are for the ex-
clusiveuseofqualiedUNICALservicetechnicians
or installers.
All the boilers are supplied already calibrated and
tested. If it is necessary to change the calibration
due to gas conversion or adaptation to the mains
supply system, the gas valve must be re-calibrated.
(Using service mode function)
MAXIMUMOUTPUT
ADJUSTMENT SCREW
MINIMUM OUTPUT
ADJUSTMENT
SCREW
B) MINIMUM OUTPUT ADJUSTMENT
- Operate the burner to a minimum power following the proce-
dure described on page 45 ‘’sweep’ function (CASCATA MAN
10 %)
- Check that the CO
2
values are within the values indicated
in the table “Burner pressures”
-
If necessary correct the value by turning the adjustment
screw “B” in a CLOCKWISE direction to increase the
value and in an ANTICLOCKWISE direction in order
to decrease it.
A) MAXIMUM OUTPUT ADJUSTMENT
- Remove the cap of the combustion gases sampling point
- Connect a suitable CO
2
gas analyser to the sampling point
in the flue outlet terminal.
- Operate the burner to the maximum power, following the pro-
cedure described on page 45 ‘’sweep’ function (CASCADE
MAN 100 %)
- Check that the C0
2
values are within the values indicated
in the table “Burner pressures”
- If necessary correct the value by turning the adjustment screw
“A” in a CLOCKWISE direction to decrease the value and
in an ANTICLOCKWISE direction in order to increase it.
WARNING!
Remove the cap 2,xredcap3 to the gas
outlet. Insert the CO2 analysis probe 4 on hole
of the cap.
Measurement. remove the cap and close the
outlet exhaust smoke cap 2.
45


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Unical MODULEX EXT 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Unical MODULEX EXT 200 in the language / languages: English as an attachment in your email.

The manual is 8,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Unical MODULEX EXT 200

Unical MODULEX EXT 200 Installation Guide - Dutch - 57 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info