16
Instructions for the installer
3.4 - BOILER LOCATION INSIDE A BOILER ROOM
Special attention shall be paid to local regulations and laws
about boiler houses and particularly to the obligation of keeping
minimum clearances and empty space around the boiler. The
installation shall be in compliance with all latest regulations and
laws about boiler houses, installations of heating and hot-water
systems, ventilation, chimneys capable of evacuating the flue
gases of condensing boilers and any other applicable require-
ment.
The boiler can be put on a flat and sufficiently strong base with
the same dimensions as the boiler ones and at least 100 mm
high (see fig. 2), in order to assemble the condensate drain
siphon. An alternative to this base may be a 100mm deep well
next to the boiler as siphon housing (see fig. 2). After installation
the boiler shall be perfectly horizontal and stable, to reduce any
possible vibrations or noises.
- Remove the casing of the boiler
- Lift the boiler with a hoist or forklift bands
- Remove the 4 screws’’A’
- Insert the 4 feet (contents into the box)
- Attach the feet to the chassis by 4 screws’’A’’previously
removed.
- Place the boiler on concrete slab and mount the casing.
3.3 - REMOVAL FROM THE BOILER BED AND INSERT FOOT
1
2
3
4
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Unical MODULEX EXT 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Unical MODULEX EXT 100 in the language / languages: English as an attachment in your email.

The manual is 8,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Unical MODULEX EXT 100

Unical MODULEX EXT 100 Installation Guide - Dutch - 57 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info