652331
29
Zoom out
Zoom in
Previous page
1/36
Next page
29
Adjustment info
°C
°C
Outlet pressure test nipple
fig. 27
2.6 - ADJUSTING THE
BURNER
All the instructions below are for the exclusive
use of qualified technicians.
All the boilers leave the factory calibrated and
tested.
If it is necessary to change the calibration fol-
lowing changes in the type of gas or adapta-
tion to the supply network conditions, it is
necessary to recalibrate the gas valve.
WARNING: During these steps do not draw
Domestic Hot Water.
For that reason it is necessary to know the
boiler operation in chimney-sweeper mode.
In order to activate this function, push and
keep depresses the reset push button for
3 seconds, on the control panel, then push
once again the same button: the display
symbols “F” and “L” will be lighted (F: blink-
ing – L: fixed) and the boiler will operate at
the maximum capacity. By pushing again
the reset push button: the display symbols
“F” and “L” will be lighted (F: blinking – L:
blinking) and the boiler will operate at the
minimum capacity. The chimney sweeper
function remains active for 15 minutes. For
cleaning this function before this fixed
period, switch OFF and ON the boiler.
To correctly regulate the gas valve, follow the
steps below:
1) Maximum output adjustment
- check the value of the supply pressure (see
table NOZZLES - PRESSURES);
- Remove the cover (A) protecting the pres-
sure regulator on the top of the modulat-
ing coil.
Connect a manometer at the outlet gas
pressure test nipple (fig. 28).
Activate the chimney sweeper function to
the maximum capacity (“F” blinking; “L”
fixed); when the burner is ignited, check
that the “MAXIMUM” pressure value cor-
responds to that indicated on the table
“NOZZLES - PRESSURES”:
- Correct eventually the value rotating the
nut “C” with a 10 mm wrench (fig. 28);
by rotating clockwise, the gas pressure
increases, anticlockwise the gas pressure
is reduced.
2) Minimum output adjustment
- Push a second time the reset push button
and the boiler will operate at the minimum
capacity (both leds F and L will blink).
- When the burner is ignited, check that the
MINIMUM pressure value corresponds to
that indicated on the table “NOZZLES –
PRESSURES, etc.
- Correct, eventually, the value rotating the
red screw “B” with a cross-screw driver or
a 6 mm wrench (fig. 28): by rotating
clockwise the gas pressure increases,
by rotating counter clockwise the gas pres-
sure decreases
GAS VALVE
A
CHIMNEYSWEEPER
ACTIVATION
OPERATION AT THE MAXI-
MUM CAPACITY
OPERATION AT THE MINI-
MUM CAPACITY
Push the reset
push button for 3
seconds
Push again the reset push
button; the symbol “F” (Cen-
tral Heating) blinks, the sym-
bol “L” (burner in operation) is
fixed.
Push again the reset push
button; the symbol “F” (Cen-
tral Heating) and the symbol
“L” (burner in operation) are
both blinking
fig. 28
F
L
F
L
Inlet
pressure
test nipple
B = Screw
(red) for
minimum
pressure
adjustment
C = Adjust-
ment nut (10
mm) for
maximum
pressure
3) Ending of basic adjustings
- check the minimum and maximum pres-
sure values of the gas valve;
- if necessary make any fine adjustments
- Clear the chimneysweeper function by cut-
ting off the voltage.
- Remove the plastic pipe from pressure test
nipple and close the inner screw;
- Using a soapy solution check for gas
leaks.
PRESSURE TEST NIPPLE
fig. 29
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Unical EVE 05 RTN 24 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Unical EVE 05 RTN 24 in the language / languages: English as an attachment in your email.

The manual is 1,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info