652334
30
Zoom out
Zoom in
Previous page
1/36
Next page
30
Adjustment info
fig. 30
1
EVE 05 CTN 24 F - EVE 05 CTN 24 - EVE 05 RTN 24
Tipe of
gas
Output
min. - max
(kW)
Input
min. - max
(kW)
Supply
pressure
(mbar)
No. of
Nozzles
Ø
Diaphragme
(mm)
Natural gas(G20)
Propan (G31)
10,17 - 24,0
10,17 - 24,0
11,5 - 26,5
11,5 - 26,5
20
37
12
12
Ø
Nozzles
(mm)
-
-
EVE 05 CTFS 24 F - EVE 05 CTFS 24 - EVE 05 RTFS 24
9,9 - 24,2
9,9 - 24,2
11,5 - 26,5
11,5 - 26,5
20
37
12
12
-
-
1,25
0,80
2,7
6,2
13,3
33,0
1,22 m³/h
0,89 kg/h
2,80 m³/h
2,06 kg/h
1,30
0,80
2,3
6,2
12,0
33,0
1,22 m³/h
0,89 kg/h
2,80 m³/h
2,06 kg/h
Gas nat. (G20)
Propano (G31)
fig. 31
JP1: For nat. gas boilers, the jumper is
on NAT.
For LPG boilers, the jumper is on
LPG.
LPG
JP1
NAT
LPG
NAT
The pressures at the burner indicated in the following table must be checked after the boiler has been operating for 3 minutes.
NOZZLES - PRESSION - DIAPHRAGME - CONSUMPTION TABLE
max.
min.
(mbar)
max
(mbar)
min.
Burner pressure
Tipe of
gas
Supply
pressure
(mbar)
No. of
Nozzles
Ø
Diaphragme
(mm)
Ø
Nozzles
(mm)
min.
(mbar)
max
(mbar)
Burner pressure
2.7 - MODIFICATION FOR
OTHER GASES
The boilers are manufactured for the type of
gas specifically required upon order.
Any subsequent conversion must be perfor-
med by qualified technicians who will use the
kits supplied by Unical and perform the con-
version and required adjustments for correct
preparation of the boiler for use.
To convert the boiler from one type of gas to
another proceed as follows:
for conversion from natural gas to LPG
- remove the main burner;
- disassemble injectors of the main burner
and replace them with those with a diame-
ter corresponding to the new type of gas
(see table “INJECTORS - PRESSURES”);
- reassemble the main burner;
- position the jumper on the modulation PCB
in the panel board as shown in fig. 31
- remove plug ‘’A’ (fig.28) on the gas valve
and fully tighten max pressure adjustment
screws ‘’B’’
- check the pressure value upstream the gas
valve (see table “INJECTORS - PRESSU-
RES”) and adjust the pressure of the bur-
ner as indicated in section “ADJUSTING
THE BURNER”
- check that the burner is functioning pro-
perly;
- check that there are no gas leaks.
- tighten the plug ”A” (fig.28) of the max
pressure adjustment screw
- when the conversion is completed, fill in
the label supplied in the kit with the infor-
mation required and stick it onto the boiler
alongside the data plate.
for conversion from LPG to natural gas
- remove the main burner;
- disassemble injectors of the main burner
and replace them with those with a diame-
ter corresponding to the new type of gas
(see table “INJECTORS - PRESSURES”);
- reassemble the main burner;
- position the jumper on the modulation PCB
in the panel board as shown in figure 31;
- remove plug ‘’A’ (fig.28) on the gas valve
- check the pressure value upstream the gas
valve (see table INJECTORS - PRESSU-
RES”) and adjust the burner pressure as
indicated in section “ADJUSTING THE
BURNER”;
- check that the burner is functioning pro-
perly;
- check that there are no gas leaks.
- tighten the plug “A” (fig.28) of the max
pressure adjustment screw;
- when the conversion is completed, fill in
the label supplied in the kit with the infor-
mation required and stick it onto the boiler
alongside the data plate.
Gas
consumption
max.
min.
Gas
consumption
Output
min. - max
(kW)
Input
min. - max
(kW)
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Unical EVE 05 CTFS 24 F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Unical EVE 05 CTFS 24 F in the language / languages: English as an attachment in your email.

The manual is 1,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info