CONDITIONS FOR USE
- This electrical domestic appliance must be connected to a mains supply of 220/240 V, 50 Hz, through a socket
with an earth connection.
- Protected with a slow acting 10 A fuse.
- Should it be necessary to use an extension lead, this will have to a minimum wire gauge of 1.5 mm
2
per terminal,
be provided with an earth wire, and be no longer than 25 m.
- There is a compartment at the rear of the appliance used for storing the mains cable.
- Do not let water get inside the appliance.
- Do not cover the air intakes or outlets on your appliance.
- If the mains cable is damaged it must be replaced. To do this, get in touch with the manufacturer, after-sales
service dept. or someone similarly qualified.
Attention!Attention!
Attention!Attention!
Attention!
This apppliance is not suitable for dehumidification at ambient temperatures of below 18This apppliance is not suitable for dehumidification at ambient temperatures of below 18
This apppliance is not suitable for dehumidification at ambient temperatures of below 18This apppliance is not suitable for dehumidification at ambient temperatures of below 18
This apppliance is not suitable for dehumidification at ambient temperatures of below 18
°
C.C.
C.C.
C.
After turning your appliance off, wait at least 3 minutes before turning it back on again. The cold circuit needs thisAfter turning your appliance off, wait at least 3 minutes before turning it back on again. The cold circuit needs this
After turning your appliance off, wait at least 3 minutes before turning it back on again. The cold circuit needs thisAfter turning your appliance off, wait at least 3 minutes before turning it back on again. The cold circuit needs this
After turning your appliance off, wait at least 3 minutes before turning it back on again. The cold circuit needs this
amount of time in order to reset.amount of time in order to reset.
amount of time in order to reset.amount of time in order to reset.
amount of time in order to reset.
MOBILITY
The appliance is fitted with wheels which allow it to be moved about. Should it be necessary to tilt the appliance
when moving it, the internal water tank will have to be emptied beforehand with the help of the drain pipe (fig.A,3)
placed onto the drain cock (fig.A,7) at the bottom of the appliance, as shown in (fig K). Once the appliance has
been put back into the upright position leave it to stand for a few minutes before switching it back on.
Attention!Attention!
Attention!Attention!
Attention!
Take special care when moving this appliance. The base is fitted with a drain outlet pipe that may break off ifTake special care when moving this appliance. The base is fitted with a drain outlet pipe that may break off if
Take special care when moving this appliance. The base is fitted with a drain outlet pipe that may break off ifTake special care when moving this appliance. The base is fitted with a drain outlet pipe that may break off if
Take special care when moving this appliance. The base is fitted with a drain outlet pipe that may break off if
knocked.knocked.
knocked.knocked.
knocked.
INSTRUCTIONS FOR USE
INSTALLATION
A) Hinge or sash windows (fig. L)
- Connect the diffuser sleeve to the warm air expulsion pipe.
- Open the window slightly and place the sleeve between the jamb and the frame.
- Close the window as far as possible and hold it with the suction cup supplied.
B) Sliding windows (fig. M)
- Connect the diffuser sleeve to the warm air expulsion pipe.
- Fit the sliding window installation accessory using the side of the window frame to support it and then
adjust it to the right height.
- Close the window as far as possible and insert the diffuser sleeve through the outlet hole.
C) Fixed installation
- Use the optional window/wall sleeving accessory which can be purchased from your usual supplier of
electrical appliances. (Ref.: B1RKZ06009)
- It will be necessary to make a hole in the wall to accommodate the hot air pipe sleeve (Fig. I).
- Take the diffuser sleeve off and connect the warm air expulsion pipe to the accessory.
AA4000/4020/8000 13/9/04, 10:2611
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ufesa AA8000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ufesa AA8000 in the language / languages: English, German, French, Portuguese, Spanish as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info