CC
High pulse pressure Above 65 mmHg
Increased pulse pressure 55 to 65 mmHg
Normal pulse pressure Below 55 mmHg
If your pulse pressure is permanently above 55 mmHg, consult
your doctor.
If the device detects irregular pulses during the
measurement, the
symbol is displayed once
the measurement is complete. This can be trig-
gered by cardiac arrhythmias, movement, talk-
ing or even by deep breathing.
The symbol is stored with the respective measurement.
13. Cardiac arrhythmia/atrial brillation/pulse disturbances
Symbol is ashing: The device has detected strong pulse
disturbances with a very fast pulse. This may be atrial -
brillation. Repeat the measurement. If the ashing symbol
appears in three consecutive measurements, be sure to
discuss this with your doctor.
Symbol is not ashing: Cardiac arrhythmia or irregular
pulse detected.
Caution: Do not confuse the irregular pulse display with the
ashing pulse display that indicates the heart rate during every
measurement (see page 51).
The device is not an instrument for the diagnosis of atrial brilla-
tion. It shows only the possibility of the presence of such a con-
dition. If this display should appear, it is essential to discuss this
with your doctor to receive an accurate diagnosis.
Measurement results accompanied by irregular pulses should be
viewed as critical and repeated under more favourable conditions.
is called the pulse pressure or pulse amplitude. The higher the
pulse pressure, the stier your vessels are thought to be.
Movements during the measurement may re-
sult in incorrect measurement values. The mo-
tion control registers stronger movements and
these are indicated by the
symbol in the dis-
play. Other disruptive factors such as speaking,
coughing or cu noises can cause the symbol to
be displayed. If this symbol appears, please re-
peat the measurement and avoid the disruptive factors.
14. Motion control
The symbol is stored with the respective measurement.
The device stores the measured values in two memories (one per
user). Each memory can store up to 120 readings and the aver-
age value (A). The average value is calculated from the last three
measurements taken.
15. Using the memory
To retrieve data, press the Memory button of
the user you wish to retrieve the data for while
the device is switched o. The average value is
displayed with „A“ (Figure 1).
Set the user whose data you wish to retrieve.
Data retrieval
Figure 1
The measured results are automatically saved in the memory. If
more than 120 measured values are saved, the oldest measured val-
ue (no. 120) is deleted so that the latest value (no. 1) can be recorded.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Uebe Visomat Double Comfort at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Uebe Visomat Double Comfort in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 2,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Uebe Visomat Double Comfort

Uebe Visomat Double Comfort User Manual - German - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info