557303
16
Zoom out
Zoom in
Previous page
1/47
Next page
Personal Adjustment and High
Altitude Diving
If you are diving at higher altitudes, make sure that the altitude mode has been
set according to the altitude of your dive site.
For information on how to select the correct altitude setting and how to use
the personal adjustment, see Section 3.5, “Personal Adjustment and High
Altitude Dives”.
Battery Power Indicator And Low Battery Warning
The IQ-400 has a unique visual Battery Power Indicator designed to give you
an advance notice of impending need to change the battery.
The Battery Power Indicator will always be seen during activation. The follow-
ing table 3.1 shows the various warning levels (see also Fig. 3.3).
14
Figure 3.4
Ready Displays
The maximum depth and
dive time are zeros (as no
dives have yet been made),
the surface interval time is
0 hours 8 minutes (in this
case eight minutes after
activization), the tempera-
ture is 22°C [72°F] and the
present depth is 0.0m [0ft].
The personal/altitude
adjustment mode is A1. The
depth display will alternate
between present and maxi-
mum depth. The Low
Battery Warning (battery
symbol) indicates that the
battery is too low for diving.
SURF
MAX
DIVE TIME
BAT
A1
¡C
A
m
S
C
S
P
E
E
D
HISLOG ALT SET PLAN
WARNING
SET THE CORRECT PERSONAL/
ALTITUDE ADJUSTMENT MODE!
When diving at altitudes greater than 700 m [2300
ft] the personal/ altitude adjustment feature must be
correctly selected in order for the computer to cal-
culate no-decompression status. The diver should
also use this option to make the calculations more
conservative, whenever it is believed that factors
which tend to increase the possibility of decompres-
sion sickness exist (see Section 3.5). Failure to prop-
erly select the personal/ altitude adjustment mode
correctly will result in erroneous data and can great-
ly increase the risk of decompression sickness.
!!
WARNING
THE IQ-400 IS NOT INTENDED
FOR USE AT ALTITUDES
GREATER THAN 2400 m (8000 ft)!
Diving at altitudes above this limit may signifi-
cantly increase the risk of decompression sickness.
!!
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tusa Imprex II IQ400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tusa Imprex II IQ400 in the language / languages: English as an attachment in your email.

The manual is 0,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info