M
A
S
DELAYED VIOLATION #2 (DV2)
If the Decompression obligation requires a Ceiling Depth between 60 FT (18 M) and 70
FT (21 M), the full NiBG and TAT (Total Ascent Time) digits will flash.
When this occurs, you must make a controlled ascent to just deeper than, and stay as
close as possible to, 60 FT (18 M) without causing the NiBG and TAT to flash. When the
Deco Stop Depth indicates 50 FT (15 M), etc., you can ascend to those Stop Depths and
continue decompressing.
DV2 Main, information includes (Fig. 63) -
> Full NiBG (flashing), O2BG if applicable
> TAT (hr:min) flashing with Deco mode icon
> Stop Depth with FT (or M) icon and STOP icon
> Stop Time (hr:min) with clock icon
> Tank icon (Gas 1 or 2)
> Current Depth with FT (or M) icon
• Press and release the A button (< 2 sec) to view ALT screens
which are similar to those previously described for the Deep
Stop (page 73).
• Depress the M button for 2 seconds to access the Gas Switch
Routine.
• Depress the S button for 2 seconds to activate the Backlight.
Fig. 63 - DV2 MAIN
66


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tusa Element II SCA282 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tusa Element II SCA282 in the language / languages: English as an attachment in your email.

The manual is 4,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info