23
GB
22
CAUTIONS FOR APA INFLATOR USAGE (APA TYPE)
In case of malfunction of APA power exhaust upon emergency such as damage of
internal wire, use oral exhaust method.
If the APA inflator main unit is dragged along a surface, for example when you reach
the bottom, then sand and pebbles may jam the APA deflation button and make
exhaust operation impossible. If exhaust operations do become impossible, either use
a normal exhaust operation or use the Rapid Exhaust Deflation to exhaust. After
exiting, carefully wash out the sand clogging the button with running water.
TUSA strongly recommends inspection, overhaul and scheduled parts
replacement at least once a year in order to ensure the optimum functioning of
the BCJ.
BCJ(CE)002-021 GB 10.11.17 9:35 AM ページ 22