557353
10
Zoom out
Zoom in
Previous page
1/32
Next page
8
APA inflator unit (APA type)
To take in air from the tank and obtain buoyancy, press the Auto inflation button.
Holding down this button can take in more air than necessary, so adjust the amount of
air by repeatedly pressing the button for a short while then releasing it. On the other
hand, air can be deflated from the BCJ to lower buoyancy by raising the APA inflator
main unit high in the direction of the water surface and pressing the regular Deflation
button. It is also possible to deflate rapidly by pressing the APA deflation button. Of
course, it is equipped with the Rapid Exhaust Deflation, which is a feature of TUSA
BCJs. This function “enables you to exhaust rapidly by grasping the APA inflator main
unit with one hand and just pulling in forward direction”. It is very important to practice
oral inflation method , manual deflation method and disconnecting LP hose to prepare
for any type of malfunction or emergency situation.
Over-Pressure Exhaust Valve
All TUSA B.C.J.’s are equipped with an Over Pressure Exhaust Valve. (O.P.E.V.)
This allows the B.C.J. to be automatically vented should air pressure in the inner
bladder become too great. O.P.E.V. valve will close once desired air pressure is
achieved, thus preventing damage to B.C.J. due to overexpansion.
3. Release button as you inhale air.
4. Continue inflation using Steps 1-3 until desired buoyancy is achieved.
Auto Inflation
To inflate B.C.J. slowly press Auto Inflation Button. (Fig. 8)
WARNING:
While inflating the B.C.J. it is recommended to have contact on the deflation button to
prevent an out of control ascent.
Oral Inflation
Procedure for Oral Inflation:
1. Before activating valve, purge any water that may be
trapped in mouthpiece by exhaling a small amount of
air into oral inflator opening.
2. With mouth still pressed against oral inflator opening,
press Manual Inflation/Deflation Button as you exhale.
(Fig. 9)
(Fig. 9)
B.C.J. INFLATION
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Tusa Buoyancy Compensator Jacket 2014 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Tusa Buoyancy Compensator Jacket 2014 in the language / languages: English as an attachment in your email.

The manual is 2,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info