7. TROUBLESHOOTING
A. FUNCTIONING TEMPERATURE
5°C ≤ Ambient Temperature ≤ 35°C When the ambient temperature is lower or higher than
the functioning temp, the dehumidifier stops.
When 5°C Ambient temp. 16°C, the compressor automatically defrosts at intervals;
during defrosting, the compressor stops and the fan keeps running.
B. BEFORE CALLING FOR SERVICE
Before contacting professional service, please review the trouble shooting list that includes
common occurrences that are not the result of a defect in workmanship or materials.
Problem Possible Cause Solution
Not working No power supply Connect to a functioning outlet and
switch on
Water Full Indication Flashes.
Water tank is full or water tank is
not assembled well.
Drain water tank and replace it back
into the unit.
Room temperature - operation
temperature is too low or too
high <5°C or >35°C
Self-Protection designed to protect
the unit. Cannot work under such
temperature.
Bad
functioning
Is the air filter clogged? Clean the air filter as instructed
Is the intake duct or discharge
duct obstructed?
Remove the obstruction from the
discharge duct or intake duct.
No air intake Is the filter clogged?
Operation temperature or
humidity is too low.
Is air outlet or air inlet blocked
Wash the filter.
Under dry environment,
dehumidifying effect will be not so
obvious.
Clean the air outlet or air inlet.
Loud noise
when running
Is the unit placed on a horizontal
and flat surface?
Place the unit correctly
Is the filter clogged? Wash the filter
Water
leakage.
Drainage pipe is not tightly
connected.
Check the drainage pipe.
Pipe is blocked. Clean the debris in pipe.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Turbionaire Smart 14eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Turbionaire Smart 14eco in the language / languages: English, German, French, Italian, Spanish as an attachment in your email.

The manual is 13.89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info