7. TROUBLESHOOTING
Symptom Inspection Solution
The unit
is not
operating.
Check the power connection in
securely.
Check if the water level indicator
lights up?
Check the room temperature.
Insert the power cord securely into
the wall Outlet
Empty the drain pan by remove the
rubber plug.
The range of operating
temperature is 5-35.
The unit
works
with
reduced
capacity.
Check the air filter for dirt.
Check if the air duct is blocked.
Check if the room door or window
is open.
Check if the desired operating
mode is selected and the
temperature is properly set.
The exhaust hose is detached.
Clean the air filter as necessary.
To clear the obstacle.
Keep the door and windows closed.
Set the mode and temperature at
proper set-point according the
manual.
Make sure the exhaust hose is
securely attached.
Water
Leakage
Overflow while moving the unit.
Check if the drain hose is kinked
or bends.
Empty the water tank before
transport.
Straighten the hose to avoid a trap
existing.
Excessive
Noise
Check if the unit is securely
positioned.
Check if any loose, vibrating parts.
Noise sounds like water flowing.
Place the unit on horizontal and
firm ground.
Secure and tight the parts.
Noise comes from flowing
refrigerant. This is normal.
ERROR
CODES
E0
E1
E2
Ft
Communication faults between
main PCB and display PCB.
Ambient temperature sensor
failure
Coil temperature sensor failures.
Condensate water high level
alarm.
Check the wire harness of the display
PCB for damage.
Check connection or replace it. To
clean or replace the temperature sensor.
Check connection or replace it. To
clean or replace the temperature sensor.
Empty the drain pan by removal the
rubber plug.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Turbionaire Revigo 14 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Turbionaire Revigo 14 in the language / languages: English, French, Italian as an attachment in your email.

The manual is 15.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info