the device;
- check that the device receives the type of gas it is manufactured
to process;
- check that the gas supply pressure does not go beyond the ma-
ximum pressure values displayed on the information plate;
- check that the gas supply system supplies the necessary amount
of gas to the device and that it is equipped with all the necessary
safety devices prescribed by current regulations.
If the user is absent for a lengthy period, turn off the main gas
supply tap.
Do not obstruct the area’s ventilation openings where the device is
installed to avoid dangers such as the build up of toxic and explosi-
ve substances. Do not utilize gas tubes to earth electrical devices.
Water connection
Connect the water heater to the water supply and insert a tap to in-
tercept the water above the device. From the front, the cold water
input is on the right and the hot water output is on the left.
Insert the lter into the water valve input tting.
Remove the plastic nut from the hot water output ttin before
connecting it to the water supply.
Check the water hardness (°f).
In case of high water hardness we recommend to install
upstream of the appliance the water softener device or other
device in compliance with the regulations including any revi-
sions.
Ensure that the tubes of you water system are not used to earth
your electrical system or telephone, they are absolutely inappro-
priate for performing this task.
In a short amount of time this can damage tubes and the device.
Disposal of waste product
This B11BS water heater is supplied with a device for releasing
ue gas.
For output of combustion by-products refer to the regulations in
force including any updates.
The gas devices with an attachment for a waste gas ue must be
connected directly to properly working chimney or ue pipe; only if
these devices are not present is it then permitted to release gases
directly outside.
The tting of devices to a chimney or ue pipe must occur via a
1 Release hood
2 Flue gas safety device
3 Water limit thermostat
4 Heat exchanger
5 Burner
6 Sensor electrode
7 Pilot burner
8 Ignition electrode
9 Injector
10 Hot water output
11 Pressure intake
12 Temperature selector
13 Venturi
14 Hydraulic valve
15 Flow regulation gas screw
16 Water lter
17 Membrane
18 Cold water input
19 Economiser
20 Gas valve
21 Safety device
22 Gas lter
23 Battery
24 Electrical card
25 Microswitch
Fig. 5
smoke channel. Smoke channels must be connected to a chim-
ney or a smoke channel in the same or adjacent area to where
the device is installed and must be made of materials resistant to
mechanical strain, heat and the effects of combustion by-products
and their condensation. The ue gas temperature must always be
above condensation temperature in all points of the smoke channel
regardless of external conditions.
FLUE GAS RELEASE SAFETY DEVICE
The product is equipped with a series of ue gas release safety
devices. The device ensures the correct release of combustion by-
products; the ow of combustible gas to the release conduit and
the smoke channel.
The safety device contains a “thermostat”, it can stop the ow of
gas to the main burner and the pilot ame.
The safety device can be triggered by the partial or total obstruction
of the release conduit or the smoke channel.
To reset the device it is necessary to press the ue gas ther-
mostat key (Fig. 6) close use a screwdriver and reopening the
hot water tap.
If the device or its electrical connections breaks down, the product
can not be put ON, it ensures a safe condition
If the device or its electrical connections breaks down, the machine
operation is blocked.
If the machine is constantly blocked as a result of the ue gas sa-
fety device, it is necessary to request the assistance of a qualied
technician accor-
ding to law in force,
to check the correct
release of ue gas
through the release
conduit and/or the
smoke channel, ac-
cording to the instal-
lation regulation.
It is highly prohibited
to attempt to modify
or remove the ue
gas safety device;
this risks the safety of
the user and persons in the area. Only a qualied technician who is
authorised by the manufacturer can meddle with the safety device
in order to check it’s functionality or to substitute it if necessary.
If it is necessary to replace the device it is vital to only use “original
parts” supplied by the manufacturer
since it has been designed, studied
and regulated to be tted with the wa-
ter heater.
A
g. 6
1 Cappa scarico
2 Dispositivo di controllo fumi
3 Termostato limite acqua
4 Scambiatore di calore
5 Bruciatore
6 Elettrodo di rilevazione
7 Bruciatore pilota
8 Elettrodo di accensione
9 Iniettore
10 Uscita acqua calda
11 Presa di pressione
12 Selettore di temperatura
13 Venturi
14 Valvola idraulica
16 Filtro dell’acqua
17 Membrana
18 Entrata acqua fredda
19 Economizzatore
20 Valvola gas
21 Dispositivo di controllo
22 Filtro gas
23 Batteria
24 Scheda elettronica
25 Microinterruttore
15 Vite di regolazione portata gas
Water Water
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TTulpe Indoor B-6 P50 Eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TTulpe Indoor B-6 P50 Eco in the language / languages: English as an attachment in your email.

The manual is 1.83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of TTulpe Indoor B-6 P50 Eco

TTulpe Indoor B-6 P50 Eco Usermanual and installation guide - German - 12 pages

TTulpe Indoor B-6 P50 Eco Usermanual and installation guide - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info