782468
7
Zoom out
Zoom in
Previous page
1/12
Next page
7
A.black
B.red
C.white
D.orange
E.blue
7.Temperature sensor
8.Water flow sensor
9.Controller Wires
10.Gas valve
11.lgnition pin
12.Controller
1.Thermostat of 77
2.Thermostat of 85
3.Controller Wires
4.Battery box
5.Wire of display
6.Temperature display
INSTALLATION
Regulations
The use of gas devices is controlled by precise regulations.
It is essential to observe all the regulations in force.
Installation of liquid petroleum gas (L.P.G) must comply with all the
distributor srequirements and those of the regulations.
Wall mounting
Warning
Do not install this device in an area that contains dust, greasy
vapor and/orcorrosive elements.
-
The device must be installed on a suitable wall surface in
proximity to a fume disposal flue
-
It is vital to leave the minimal distances around the device as
shown in fig 3 to allow for maintenance operations to take place.
Location
The water heater must not be tightly placed in an enclosure or slot,
it should have an adequate flow of air around it
-
The water heater must not be placed above a kitchen or other
cooking devices that might deposit grease vapor on its exterior
leading to corrosion
-
Surfaces that sensitive to heat (e.g.wood)must be protected
using appropriate insulation.
-
Fig.1 displays the dimensions necessary for wall mounting
Room ventilation
The installation of the water heater must comply with regulations in
force including any updates.
Warning: This device can only be installed in venues that are
permanently ventilated according to regulation in force.
Air circulation
It is vital that areas where gas devices are installed (type B) have
access to the amount of air necessary for the regular combustion of
gas as well as the ventilation of the venue.
-
It is prohibited to use an extractor fan, fireplaces, and other
similar devices at the same time as the water heater
-
The area where the water heater is installed must have a regular
flow of air for ventilation.
Air flow
The flow of air must occur by the following means:
-
Permanent openings in the wall that lead outdoors
-
Single or collective ventilation ducts.
The air used for ventilation must be taken directly from an outside
location,that is far from sources of pollution.
Indirect ventilation from adjacent areas are permitted with the fol-
lowing limitations:
-The adjacent area is equipped with direct ventilation
-The devices within the area to ventilate are connected to a waste
duct
-The adjacent area does not contain a bedroom and is not a com-
mon area;
-The adjacent area is not a fire hazard such as a storage area for
flammable materials,garage etc.
-The adjacent area is not lower than the area to ventilate as this
might lead to an opposing draught (this can be caused by other
devices that operate on the basis of combustion,a fireplace or
any suction device that have not been given an adequate air
supply)
-The air flow from the adjacent area occurs freely through permanen
topenings.
Electrical connection to battery
The device is powered by two 1.5 V batteries, alkaline long-lasting
model LR20, thus it is not necessary to connect the device to a
power socket.
Gas connection
Determine the pipe diameter according to current regulations.
Before installing the device blow in the gas pipe to eliminate any
residue from its manufacturing. Connect the water heater to the
inter nal system sgas pipes and place a tap above the device for
the halting and release of gas.
The main gas supply pipe must be connected by a flat seat fitting
that allows the insertion of a gasket specifically provided for gas
connections.
Do not use a conical seat fittings or union conical with threading
sealed with hydraulic hackled hemp or Teflon.
The water heaters that are powered by tanks of L.P.G. gas with
regulation and interception devices, must be connected correctly
so to guarantee the safety of persons and the surrounding area.
Foll ow all related regulations.
50 50
200
Fig.3
Fig.4
Fig.5
148.00 mm
210.00 mm
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TTulpe Indoor B-10 N20 Eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TTulpe Indoor B-10 N20 Eco in the language / languages: English as an attachment in your email.

The manual is 6.19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of TTulpe Indoor B-10 N20 Eco

TTulpe Indoor B-10 N20 Eco Usermanual and installation guide - German - 12 pages

TTulpe Indoor B-10 N20 Eco Usermanual and installation guide - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info