782477
20
Zoom out
Zoom in
Previous page
1/24
Next page
20
To calibrate the gas valve (standard procedure MANU: it is possible to
deviate from the value set by approximately +/-1.5 mbar) carry out the
following operations:
hPlace the electric switch of the system to off
hRemove the casing by unscrewing the fastening screws located at the
bottom of the water heater and detached the casing from the top
hRemove the cover that closes the service inlet (located on the
shelf - Fig 11) and insert through the hole the silicon pressure
gauge tube
hLoosen by approximately two turns the screw of the pressure tap
downstream of the gas valve and connect the pressure gauge to it
hCarefully close the casing and place the electric switch of the sys-
tem to on
hAccess the Calibration Menu
hOpen the hot water tap and wait until ignition of the burner.
Upon activation of the menu will appear rst the word Ma and then the
word to to compose Manu and will appear, indicating that the
water heater is operating at maximum capacity.
hTurn the knob until visualize on the pressure gauge the maximum
burner pressure (see data table)
hTo store the value press the reset button
hPress the reset button to select the next lowest setting value
hTurn the knob until visualize on the pressure gauge the minimum
burner pressure (see data table)
hTo store the value press the reset button
hPress the reset button until MENU’ ashing, release the button:
the display shows
hPress again the reset button until the display shows MENU’ ashing,
release the button: the display shows the set point temperature
hClose the hot water tap.
The calibration operation ends automatically after 15 minutes of
inactivity or in the case of overheating (67°C)
Alarm history menu
This feature allows displaying of the last 10 errors that have occurred on
the appliance.
Upon activation of the menu, the gures (index of the last stored
error), the error code and the word (es: => => ) will
appear alternately.
Turning the knob it is possible to scroll through the errors index. Display
ranges from the most recent to the earliest.
If the user pauses, the display shows the letters AL to indicate access
within the errors history menu.
Press the reset button until MENU’ ashing, release the button: the di-
splay shows .
Press again the reset button until the display shows MENU’
ashing, release the button: the display shows the set point tem-
perature.
Info menu
This feature allows displaying:
hLast version of software review
hHot water temperature in direct
hHot water quantity in direct (l/min).
This menu is active during all the production of instant hot water.
Exiting the menu takes place automatically after 15 minutes of
inactivity or by pressing the reset button.
Fig. 25 - “Alarm History Menu” Activation
Fig. 24 - “Calibration Menu” Activation
Fig. 26 - “Info Menu” Activation
Eco
Eco
Eco
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for TTulpe C-Meister 11 P37 Eco at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of TTulpe C-Meister 11 P37 Eco in the language / languages: English as an attachment in your email.

The manual is 1.78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of TTulpe C-Meister 11 P37 Eco

TTulpe C-Meister 11 P37 Eco Usermanual and installation guide - German - 24 pages

TTulpe C-Meister 11 P37 Eco Usermanual and installation guide - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info