4
1. Repairs may only be
carried out by an expert.
Due to the design,
the heater front
case will become
hot during opera-
tion. The operator is obliged
to ensure that due care is tak-
en to protect third parties
(small children in particular).
2. The heater’s hot air outlet
should under no circum-
stances be blocked. Never
hang clothes or similar in
front of or on top of the
heater to dry. This could
cause serious damage to the
heater as a result of overheat-
ing. Do not place inflamma-
ble materials near the heater!
Please observe these instruc-
tions for your own safety.
3. When operating a brand-
new heater for the first time
(or after it has been idle for a
lengthy period) you may tem-
porarily notice a slight smoke
and smell. We advise running
the heater at full power and
thoroughly ventilating the
room.
4. Any modifications to the
appliance or the use of spare
parts and accessories impor-
tant for operation which are
not original Truma parts, or
non-observance of the in-
structions for installation and
use will result in the guaran-
tee becoming invalid and no
liability will be assumed. Fur-
thermore, the approval for
operating the appliance will
become invalid and in some
countries also the approval
for operating the vehicle.
5. In order to prevent the
power cable for the caravan
from overheating (minimum
cross-section 3 x 2.5 mm
2
)
the cable drum must be fully
unwound.
Technical Data
Power supply:
230 V ~, 50 Hz
Power consumption at
power setting
500 W: 2.2 A
1000 W: 4.5 A
2000 W: 8.5 A
Weight: approx. 3.8 kg
Declaration of conformity:
Ultraheat Solo is a tested
230 V electric heater and
complies with the require-
ments of EN 60335, EMC di-
rective 80/336/EEC, low volt-
age directive 73/23/EEC and
the associated EC standards
and technical specifications,
and is therefore entitled to
bear the CE symbol.
Installation example
1 Truma-Ultraheat Solo
2 Control panel with
thermostat
3 Trumavent fan and
comfort kit with Airmix
(for warm air distribution
- optional),
Ultraheat Solo
Electric heating 230 V, 2000 W
Accessories
1. Extension cable for the con-
trol panel, length 5-metres (Art.
no. 34300-01; not illustrated).
2. Remote sensor FFC 2,
monitors the room tempera-
ture, regardless to the posi-
tion of the control panel,
comes with a 4 m connecting
cable (Art. no. 34201-01).
The remote sensor must not
be placed in the vicinity of ex-
ternal heat sources (cookers,
lamps, opposite warm air
vents etc.) or in locations in
which heat can accumulate
(below shelves, in corners,
behind curtains).
If heating power of more than
2000 W is required (e.g. for
winter camping) the Trumatic
S 3002 liquid gas heater with
heating power of 3700 W can
be retrofitted without prob-
lems (retrofit kit complete
with exhaust system, Art. no.
31311-06).
Important operating notes