484598
26
Zoom out
Zoom in
Previous page
1/48
Next page
26
Dati tecnici
(rilevati secondo EN 624 e / o condizioni di controllo Truma)
S 3004 / S 3004 P / S 5004
Tipo di gas
Gas liquido (propano / butano)
Pressione d‘esercizio
30 mbar (vedi targa dati)
Potenza calorifica nominale
S 3004 / S 3004 P: 3500 W
S 5004: 6000 W
Consumo di gas
S 3004 / S 3004 P: 30 – 280 g/h
S 5004: 60 – 480 g/h
Indicazioni supplementari conformi EN 624
S 3004 / S 3004 P: Q
n
= 4,0 kW (Hs); 290 g/h; C
51
; I
3B/P
S 5004: Q
n
= 6,8 kW (Hs); 490 g/h; C
51
; I
3B/P
Paesi di destinazione
BE, BG, RO, DK, DE, EE, FI, FR, GB, UK, IS, IE, IT, LV, LT, LU,
MT, NL, NO, AT, PL, PT, SE, CH, SK, SI, ES, CZ, HU, CY
Tensione d‘esercizio
1,5 V (accenditore automatico con funzionamento batteria)
Corrente assorbita
225 mW (accensione)
Peso
S 3004 / S 3004 P: ca. 10,3 kg (senza ventilatore)
S 5004: ca. 17,5 kg (senza ventilatore)
Misure
S 3004 / S 3004 P
500
503*
90
92*
281
122
102**
545
528
480
S 5004
120
122*
374
217
530
533*
568
550
501
102**
* Con listello ornamentale cromato
** Truma Ultraheat (opzionale)
Misure in mm con tolleranza + 2 mm / - 1 mm
Il produttore si riserva la facoltà di apportare modifiche
tecniche!
Dichiarazione di conformità
1. Dati principali del produttore
Nome: Truma Gerätetechnik GmbH & Co. KG
Indirizzo: Wernher-von-Braun-Str. 12, D-85640 Putzbrunn
2. Identicazione dell‘apparecchio
Tipo / modello:
Stufa LPG / S 3004 / S 3004 P / S 5004
(Rispettivamente con e senza Ultraheat)
3. Soddisfa i requisiti delle seguenti direttive
3.1 Direttiva 2009/142/CE sugli apparecchi a gas
3.2 Direttiva UN ECE R122 relativa al riscaldamento dei veicoli
a motore e dei loro rimorchi
3.3 Direttiva 2004/108/CE relativa lla compatibilità
elettromagnetica
3.4 Direttiva relativa alla soppressione dei disturbi radioelettri-
ci nei veicoli a motore 2009/19/CE, UN ECE R10
3.5 Direttiva 2006/95/CE bassa tensione
3.6 Direttiva 2000/53/CE relativa ai veicoli fuori uso
ed è dotato dei numeri di omologazione del tipo E1 10R-036531
S 3004 / S 3004 P E1 122R–000361
S 5004 E1 122R–000362
e del marchio CE di conformità con il numero di identificazione
del prodotto
S 3004 / S 3004 P CE-0085CM0287
S 5004 CE-0085CM0288
4. Fondamento della verifica della conformità
DIN EN 624, DIN EN 437, DIN 3362,
EN 61000-6-1, -6-3, -3-2, -3-3, EN 55014-1, -2,
EN 62233, EN 60335-1, EN 60335-2-30;
5. Centro di controllo
Kraftfahrt-Bundesamt (ufficio centrale della motorizzazione),
DVGW (agenzia tedesca per l‘acqua e il gas)
6. Indicazioni relative alla funzione del firmatario
Firma: Dr. Andreas Schmoll
Direzione tecnica Putzbrunn, 13.09.2011
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trumatic S 5004 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trumatic S 5004 in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 7,53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info