Operating instructions
Intended use
This appliance has been designed for installation in natural gas
operated vehicles. It is not approved for installation in boats.
Other applications are also possible following consultation
with Truma.
Always observe the opera ting instructions and “Impor-
tant operating notes” prior to starting! The vehicle owner
is responsible for the correct operation of the appliance!
The installer or vehicle owner must apply the yellow sticker
with the warning information, which is enclosed with the ap-
pliance, to a place in the vehicle where it is clearly visible to all
users! Ask Truma to send you stickers, if necessary.
Control panel with sliding switch
ab
a = Slide valve
Heating – Off – Ventilation
b = Slide valve for
high setting (large flame symbol)
low setting (small flame symbol)
Control panel with rotary switch
Trumatic E
1
3
5
7
9
d
c
e
c = “Heating” rotary switch
high setting (large flame symbol)
low setting (small flame symbol)
d = “Off” rotary switch
e = “Ventilation” rotary switch
high setting (large symbol)
low setting (small symbol)
Switching on the Heating
Remove cowl cap.
Open gas extraction valve.
Open quick-acting valve in the gas supply line.
Adjust desired room temperature at rotary knob.
Switching the heating on:
Control panel with sliding switch
Set the switch (a) to Heating and switch (b) to the desired
output setting.
Control panel with rotary switch
Set the rotary switch to the desired output setting (c).
If the outside temperature is low, switch to high setting.
The Trumatic E heater has been tested and approved for
operation, also when the vehicle is moving. The burner
with fan assistance guarantees satisfactory operation, even
under extremely windy conditions. National restrictions for
the operation of gas equipment while driving may need to be
taken into consideration.
Switching on the Ventilation
Control panel with sliding switch:
Set switch (a) to Ventilation and switch (b) to the desired
output setting.
Control panel with rotary switch:
Set the rotary switch to the desired output setting (e).
Switching off
Set the sliding switch (a) or the rotary switch (d) to the centre.
If the appliance is switched off after a heating phase, the fan
can continue running in order to make use of the residual
heat.
If the device is not used for a long period, put on cowl cover
and close quick-acting valve in the gas supply line.
Green indicator lamp “Operation
(under rotary control knob)
When the appliance is switched on (heating or ventilation) the
green indicator lamp must be illuminated (the fan is running).
If the indicator lamp is not illuminated, possibly check the
(main) switch. For this purpose observe respective instructions
of the vehicle manufacturer.
During the heating operation, while the flame is burning, the
green indicator lamp lights up with twice the intensity. This
also makes it possible to determine the instantaneous
switching point of the room temperature.
Fuses
The device and control panel fuses are on the electronic
control unit on the device.
Device fuse (F1): 3.15 AT – slow – (EN 60127-2-3)
Control panel fuse (F3): 1.6 AT – slow –
The fine-wire fuse must only be replaced by a fuse of the
same design.
Red indicator lamp “Failure”
Should a failure occur, the red indicator is illuminated per-
manently. Possible causes for the failure can be e.g. no gas,
insufficient combustion air, heavily soiled rotor, defective fuse
etc.. Deactivate by switching off and then switching on again.
Opening a window to which a window switch is fitted
and closing it again is the equivalent of switching off / on
at the control panel (e.g. a fault reset)!
Flash operation indicates that the operating voltage is too
low or too high for the appliance (charge battery, if necessary).
In Germany, always notify the Truma Service Centre if prob-
lems are encountered; in other countries the relevant service
partners should be contacted (see Truma Service Booklet or
www.truma.com).
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trumatic E 2400 E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trumatic E 2400 E in the language / languages: English, German as an attachment in your email.

The manual is 0,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trumatic E 2400 E

Trumatic E 2400 E User Manual - English, German - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info