Fault
Cause
Rectification
After switching on
(winter and summer opera-
tion) none of the LEDs are lit.
No operating voltage.
Device fuse or vehicle fuse
defective.
Check 12 V battery voltage, charge if necessary.
Check all electrical plug connections.
Check the unit or vehicle fuse and replace if necessary
(see fuses).
The green LED comes on
when the unit is switched
on, but the heater does not
operate.
The temperature setting
on the control panel is
lower than the room
temperature.
Select higher room temperature at the control panel.
Green LED flashes after
heater is switched off.
After-running is active in
order to reduce the unit’s
temperature.
No error. Coasting operation switches off after
max. 5 minutes.
Red LED flashes 6 x. Insufficient fuel due to
insufficient fuelling, empty
tank, and / or inclined
vehicle orientation.
Fill tank with fuel. Then fill the fuel line as described under
“Initial start-up”.
Red LED flashes (except
6 times) or red LED shines.
Malfunction of the heating
device.
Please contact the Truma Service Centre.
Yellow LED flashes 1 x. Possible under-voltage
< 11.5 V.
Use the electrical power from the battery carefully,
e.g. restrict lighting.
Charge battery.
Yellow LED flashes 2 x. Under-voltage < 10.2 V. Check battery voltage, charge if necessary.
Short-term immediate measure: switch off heavy load
or start up vehicle engine until the heater starts running
(approx. 4 minutes).
Battery capacity inadequate, if necessary exchange old
battery.
Over-voltage > 16.4 V. Check the battery voltage and power supply such as e.g.
the charging device.
Yellow LED flashes 3 x.
Yellow LED flashes 4 x.
Open window above cowl
(window switch).
Warm air temperature
and / or water temperature
exceeded:
Not all warm air ducts
are connected.
Hot-air outlets blocked.
Recirculated air intake
blocked.
Summer operation with
empty water tank.
Close window.
Check whether the 4 warm air ducts are connected.
Check individual outlet apertures.
Remove blockage from recirculated air intake.
Fill boiler with water.
Yellow LED flashes 5 x. Room temperature sensor
or cable defective.
Please contact the Truma Service Centre.
Yellow LED flashes 6 x. Water temperature
exceeded in summer
mode.
Fill boiler with water.
Yellow LED flashes 7 x. Control panel or control
panel cable defective.
Please contact the Truma Service Centre.
Trouble-shooting list
Flash code on the control panel
Flash sequence LED:
On: 0,5 seconds
Off: 0,5 seconds
Pause between the flashing sequence: 3 seconds
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trumatic Combi D 6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trumatic Combi D 6 in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 0,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info