484616
14
Zoom out
Zoom in
Previous page
1/60
Next page
14
Draining the water heater
Switch off power to water pump (main or pump switch).
Open hot water taps in kitchen and bathroom.
Turn the rotary switch on the drain valve (FrostControl) by 180°
until it engages, whereby the push button moves out and the
drain valve opens.
The boiler is now drained directly to the outside via the drain
valve. Place a bucket beneath the outlet to check whether the
water content has completely drained away (10 litres). There
shall be no claims under guarantee for damage caused
by frost!
Maintenance
Only original Truma parts may be used for maintenance and
repair work!
We recommend the Truma system care set for cleaning, dis-
infecting and looking after the boiler. Other products – in par-
ticular products containing chlorine – are unsuitable.
The effectiveness of the use of chemicals to combat microor-
ganisms in the unit can be increased by heating the water in
the boiler to 70 °C at regular intervals.
Move the rotary switch on the control panel to position (c –
summer operation) 60 °C. The green (b) and yellow (g) LEDs
light up.
Once the water in the boiler has reached a temperature
of 60 °C, the burner will switch off and the yellow LED (g)
will go out. The unit must stay switched on for at least 30 min-
utes and no warm water may be removed. The residual heat in
the heat exchanger will heat the water up to 70 °C.
Fuses
The unit’s fuse is located on the electronics under the connec-
tion cover. Replace the unit’s fuse only with an identical fuse.
Device fuse: 10 A – slow – (T 10 A)
T 10 A
Disposal
The device must be disposed of in line with the administra-
tive regulations of the respective country in which it is used.
National regulations and laws (in Germany, for example, the
End-of-life Vehicle Regulation) must be observed.
In other countries, the relevant regulations must be observed.
Technical data
(determined in accordance with EN 624 or Truma test
conditions)
Device category
I
3 B/P
in accordance with EN 437
Type of gas
Liquid gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Water contents
10 litres
Heating up time from approx. 15 °C to approx. 60 °C
Boiler approx. 20 minutes (measured according to EN 15033)
Heater + boiler approx. 80 min.
Pump pressure
max. 2.8 bar
System pressure
max. 4.5 bar
Rated thermal output (automatic output levels)
Combi 4: 2000 / 4000 W
Combi 6: 2000 / 4000 / 6000 W
Gas consumption
Combi 4: 160 – 320 g/h
Combi 6: 160 – 480 g/h
Readiness-heat power requirement Combi 4 / Combi 6: 5.2 g/h
Air delivery volume (free-blowing without hot-air pipe)
Combi 4: with 3 hot-air outlets max. 249 m³/h
with 4 hot-air outlets max. 287 m³/h
Combi 6: with 4 hot-air outlets max. 287 m³/h
Current input at 12 V
Heater + boiler
Combi 4: Short-term max. 5.6 A
(average power consumption 1.1 A)
Combi 6: Short-term max. 5.6 A
(average power consumption 1.3 A)
Heating up of boiler: 0.4 A
Stand-by: 0.001 A
Heating element FrostControl (optional): maximum 0.4 A
Weight (without water contents)
Heater unit: 14.0 kg
Heater unit with peripheral devices: 14.5 kg
The right to effect technical modifications is reserved!
Dimensions
450 mm
510 mm
300 mm
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trumatic Combi 6 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trumatic Combi 6 in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 2,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info