Trouble-shooting list
Fault Cause Rectification
No LED is shining, the device
is switched on and is supplied
with operating current.
Automatic restart is
blocked, e.g. after a power
failure.
Reset (fault reset) by switching off, waiting 5 seconds
and then switching on again.
After switching on (winter and
summer operation) none of the
LEDs are lit.
No operating voltage.
Device fuse or vehicle fuse
defective.
Check 12 V battery voltage, charge if necessary.
Check all electrical plug connections.
Check the unit or vehicle fuse and replace if necessary
(see fuses).
The green LED comes on when
the unit is switched on but the
heater does not operate.
The temperature setting on
the control panel is lower
than the room temperature.
Select higher room temperature at the control panel.
After switching on the heating
system, the green LED shines
and
the red LED flashes with 5 Hz,
the red LED flashes with 1 Hz,
the red and the yellow LEDs
flash alternately with 1 Hz.
Open window above cowl
(window switch).
Under-voltage.
Battery voltage is too low
< 10.0 V.
No 230 V operating
voltage.
230 V fuse defective.
Overheating protection has
activated.
Threatening under-voltage.
Battery voltage is too low
< 10.4 V.
There is a threat of under-
voltage when heating up
the water.
Battery voltage is too low
< 10.4 V.
Close window.
Charge battery. If necessary replace old battery.
Re-establish 230 V operational voltage.
Replace 230 V fuse.
Reset overheating protection. Allow heater to cool,
remove connection cover and press reset button.
Charge battery.
Charge battery.
After the heater is switched on,
the green LED is lit and the red
LED blinks.
Electronics are defective. Please contact the Truma Service Centre.
Approximately 30 seconds after
the heater is switched on, the
red LED is lit.
Gas cylinder or quick-clo-
sure valve in the gas line is
closed.
Combustion air infeed or
exhaust outlet is sealed.
Check gas supply and open valves.
Inspect openings for contamination (slush, ice, leaves,
etc.) and remove contamination if necessary.
After operating for a longer pe-
riod of time, the heater switches
to failure.
Summer operation with
empty water tank.
Hot-air outlets blocked.
Recirculated air intake
blocked.
Gas pressure regulator
iced up.
Butane content in the gas
cylinder too high.
Switch device off and allow to cool. Fill boiler with
water.
Check individual outlet apertures.
Remove blockage from recirculated air intake.
Use regulator heating (EisEx).
Use propane (at temperatures below 10 °C in particu-
lar, butane is unsuitable for heating purposes).
Green and red LEDs flash (with
5 Hz) after the heating system
has been switched off.
Green LED flashes (with 5 Hz)
after the heating system has
been switched off.
Unit was switched off dur-
ing failure. After-running
is active in order to reduce
the unit’s temperature.
After-running is active in
order to reduce the unit’s
temperature.
After-running will switch off after a few minutes. Only
at that time will a failure reset be possible (switch off
and then back on).
No failure. After-running will switch off after approxi-
mately 5 minutes.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trumatic Combi 4 E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trumatic Combi 4 E in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 2,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info