631208
5
Zoom out
Zoom in
Previous page
1/16
Next page
Always observe the operating instructions prior to
starting! The vehicle owner is responsible for the correct
operation of the appliance.
The installer or vehicle owner must apply the yellow sticker
with the warning information, which is enclosed with the
appliance, to a place in the vehicle where it is clearly visible to
all users (e.g. on the wardrobe door)! Ask Truma to send you
stickers, if necessary.
Before using the first time, it is essential to flush the
entire water supply through with clean warm water.
Always mount the cowl cap when the water heater is not be-
ing operated! Drain the water heater if there is a risk of frost!
There shall be no claims under guarantee for damage
caused by frost!
Materials in the device which come into contact with water
are suitable for use with drinking water (see manufacturer
declaration: www.truma.com – Manufacturer Declaration).
Filling the Truma Ultrastore with water
Check that the safety/drain valve in the cold water intake is
closed: Lever should be in horizontal position, position (e).
e
e
f
e = Lever position “Closed”
f = Lever position “Drain”
Open hot tap in bathroom or kitchen, with pre-selecting mix-
ing taps or single-lever fittings set to “hot”.
Switch on power for water pump (main switch or pump switch).
Leave the tap open to let air escape while the water heater is
filling. The heater is filled when water flows out of the tap.
Residues of frozen water can prevent filling if there is a frost.
The water heater can be defrosted by switching on the heater
for a short period (max. 2 minutes). Frozen pipes can be
defrosted by heating the room.
Draining the water heater
If the mobile home is not used during periods of frost, it
is essential that the Truma Ultrastore be emptied.
Disconnect power for water pump (main switch or pump
switch).
Open hot water taps in bathroom and kitchen.
Open safety/drain valve: Lever in vertical position, position (f).
The water heater is now drained directly to the outside via the
safety/drain valve. Check that the water contents have been
completely drained (10 litres).
Switching on Gas operation
Ultrastore
50°
70°
b
c
b
a
a = Red LED “Failure”
b = Water heater “On” 50 °C or 70 °C
c = Water heater “Off”
Never operate the water heater without water in it!
If the cowl is positioned vertically below an opening part of
a window, the water heater must be fitted with an automatic
shut-off device to prevent operation when the window is open.
Remove cowl cover.
Open gas cylinder and open quick-acting valve in the gas sup-
ply line.
Switch on water heater at the switch on the control panel (b).
When using the vehicle switches: refer to operating instruc-
tions of the vehicle manufacturer or see switch labels.
If there is air in the gas supply line, it may take up to a minute
before the gas is available for combustion. If the appliance
switches to “Failure” during this period, switch off the appli-
ance – wait 5 minutes – and switch on again!
Switching off
Switch off the water heater (c). Mount cowl cap. Drain the
water heater if there is a risk of frost. Close quick-acting valve
in the gas supply line if the appliance is not to be used for a
longer period of time and close the gas cylinder.
Red LED “Failure”
The red LED (a) lights up if there is a failure. For possible caus-
es please refer to page 7. To unlock, switch off the appliance,
wait 5 minutes, and switch on again.
Switching on Electric operation
(230 V ~, 850 W, 3.7 A / 1300 W, 5.7 A)
Ultrastore
230 V ~
g – 850 W
h
g – 1300 W
g = Water heater “On” 850 W or 1300 W
h = Water heater “Off”
Never operate the water heater without water in it!
Switch on at the control panel (g).
When using the vehicle switches: refer to operating instruc-
tions of the vehicle manufacturer or see switch labels.
The water temperature cannot be selected, automatic
temperature limitation at approx. 70 °C! For a faster
heating up period the appliance can be simultaneously oper-
ated with gas and electrical power.
Operating instructions
5
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma Ultrastore Rapid GE at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma Ultrastore Rapid GE in the language / languages: English as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info