629588
12
Zoom out
Zoom in
Previous page
1/44
Next page
12
Making sure the gas
flow monitor is working
properly
The functionality of the gas flow
monitor is directly related to
how the gas pipe was installed.
For this reason, it must be
checked individually for every
type of vehicle. This test must
therefore be a permanent part of
the design procedure! We also
recommend a functional test as
part of series production in order
to counteract negative effects
caused by any changes to the
installation procedure.
– Open all stop valves.
– Remove the first heating unit
from the line and close the line
temporarily.
– Bring the gas system into
operation (see “Operating
instructions”).
– Open the temporary seal. Gas
may flow out for only a short
time before the gas flow moni-
tor is triggered.
If the gas flow monitor
does not activate, please
contact the Truma service centre.
– Screw the heating unit onto
the gas line.
– If you have more than one
heating unit, you must per-
form the test separately for
each one!
– Conduct the leak test (see
“Checking the low pressure
area for leaks”).
Sticker
The installer or vehicle owner
must affix the yellow operating
instruction sticker that is pro-
vided with the unit to the vehicle
in a location that is clearly visible
to all users.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma SecuMotion Gastank at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma SecuMotion Gastank in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 1,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info