1 = rotary switch position “Operation
2 = push button position “Closed”
3 = push button position “Drain”
4 = drainage muff (led outside through floor of vehicle)
Filling the boiler (water tank)
Check whether the rotary switch (setting 1) points to
Operation” and is clicked into place.
Close the drain valve by pressing the push-button (setting 2).
The push-button must click into the “Closed” position.
Only when the temperature around the drain valve is
over around 7 °C can it to be closed manually with the
press button (setting 2) and the boiler filled. At temperatures
below 7 °C it is advisable to switch on the vehicle heating
system to heat up the inside of the vehicle.
Operating instructions
The FrostControl heating element (accessory for Combi
heating systems) cannot be used for boilers and the
Trumatic C because they lack the required connection.
Automatic opening of the drain valve
If the temperature around the drain valve is below about 3 °C,
it will open automatically and the push button will disengage
(outward movement) (setting 3). The water from the boiler will
be released through the drainage muff (4).
The opening of the drain valve or the free drainage of
the water can be impeded by various environmental
influences, therefore Truma cannot assume any liability for
frost damage.
Manual opening of the drain valve
Turn the rotary switch by 180° until it engages, whereby the
push button moves out (setting 3). The water in the boiler
drains out through the drainage muff (4).
Closing the drain valve
Check if the rotary switch is set to “Operation” (setting 1),
meaning that it is parallel to the water connection and engaged.
Close the drain valve by activating the push button. The push
button must engage in position (2) “Closed”.
Only when the temperature around the drain valve is over
around 7 °C can it to be closed manually with the press button
(setting 2) and the boiler filled.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma FrostControl at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma FrostControl in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 2,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info