Water connection
Any pressure or immersion pump up to 2.8 bar can be used to
operate the boiler, as can any mixing battery with or without
an electric switch.
If connected to a central water supply (rural or urban con-
nection), or if more powerful pumps are being used, a press-
ure reducer must be used, which will prevent pressures high-
er than 2.8 bar from occurring in the system.
If using immersion pumps, a non-return valve (10–not in-
cluded in scope of delivery) must be installed between the
pump and the first branch (arrow indicates flow direction).
10
13
12
14
Figure 6
When pressure pumps with a large switching hysteresis are
being used, hot water may flow back via the cold water valve.
We recommend installing a non-return valve (11–not in-
cluded in scope of delivery) between the outlet to the cold
water tap and the drain valve as a return flow inhibitor.
14
11
13
12
Figure 7
In order to ensure that all the water is drained from the
boiler and that all water connections are leak-tight, the
water connections (12 + 13) and the drain valve (14) must
always be used.
Flexible hose installation
Truma can supply the water connections (12+13) and the
drain valve (14) with hose connection, diameter 10mm, as
accessories.
Pressure-resistant (up to 4.5bar), hot water-resistant (up to
+80 °C) , food-safe water hoses with an inner diameter of
10mm must be used.
Water hoses must be as short as possible and free of
kinks. All hose rubber connections must be secured
with hose clamps (including the cold water connection). The
warming of the water and its resulting expansion may gener-
ate pressures of up to 4.5bar in the drain valve (also occurs
with immersion pumps).
Route all water lines so they slope downwards to the
drain valve. Otherwise there is a risk of frost damage
that is not covered by the warranty!
Rigid duct installation using the John Guest
system
Truma can supply the water connections (12+13) and the
drain valve (14) with a diameter of 12mm as accessories. In
this case it is advisable to always use John Guest pipes, inser-
tion sleeves and locking rings.
Suitable adapters (not included in scope of delivery) must be
used for connecting rigid pipelines with a different diameter.
Route all water lines so they slope downwards to the
drain valve. Otherwise there is a risk of frost damage
that is not covered by the warranty!
Installing the drain valve
Fit drain valve(14) in an easily accessible location in the vicin-
ity of the boiler. Drill hole with diameter of 18mm and insert
the drainage socket with hose(15). Secure the drain valve in
place with 2screws. Water removal can take place directly to
the outside in a splash-protected location (fit splash guards if
necessary).
Ø 18 mm
14
15
Figure 8
Water line routing
Connect cold water supply(16) to drain valve(14). The direc-
tion of flow is irrelevant.
14
16
13
12
22
20
23
Figure 9
Push elbow fitting without aeration valve(13) as far as poss-
ible onto the boiler’s cold water connection tube (lower tube),
and push the elbow fitting with built-in aeration valve(12) as
far as possible onto the boiler’s hot water connection tube
(upper tube). Pull in the opposite direction to check that the
elbow fittings are securely attached.
Slide venting hose with an outer diameter of11mm (20) onto
the hose nozzle of the aeration valve (21) and route to the out-
side free of kinks. Radius of arc must not be less than 40 mm.
10
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma BG 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma BG 10 in the language / languages: English, German, Dutch, Danish, French, Italian, Swedish as an attachment in your email.

The manual is 5,43 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Truma BG 10

Truma BG 10 User Manual - English, German, Dutch, Danish, French, Italian, Swedish - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info