Screw the boiler securely to the floor of the vehicle with
at least two shackle plates (11) with the screws provided,
B 5.5 x 25, on a suitable base (plywood panel, laminated
wood strips, or metal base).
Water connection
All pressure and submergible pumps up to 2.8 bar are used
for operating the boiler and all mixed combination sets with
or without an electrical switch.
Fig. B
When using immersion pumps, a non-return valve (12 – not
included in the scope of supply) must be fitted between the
pump and the first branch point (arrow points in direction of
flow).
Fig. C
When using pressure pumps with high switching hysteresis,
hot water may flow back through the cold water tap. To pre-
vent the backflow, we recommend that a non-return valve
(6 – not included in the scope of supply) be fitted between the
outlet to the cold water tap and the drain valve.
Pressure and hot water-resistant hoses with an internal diam-
eter of 10 mm should be used for the boiler and the safety/
drain valve connections.
For non-flexible pipe routing (e.g. John Guest System) Truma
can supply the water connections (15 + 16), the safety/drain
valve (13) and a non-return valve (12 + 6) with a 12 mm diam-
eter inner connection as accessories.
If connecting to a central water supply (rural or city connec-
tion) or when using more powerful pumps, a pressure reducer
must be used which prevents pressures of greater than
2.8 bar occurring in the boiler.
Route the water hoses so that they are as short and
free of kinks as possible. All hose connections must be
secured using hose clamps (also for cold water)! Pressures
of up to 3.5 bar can occur in the safety/drain valve (also in
submergible pumps) because of the heat of the water and the
resulting expansion.
Hose clips (part no. 40712-01) are recommended for attaching
the hoses to the wall or the floor. If gas heating has been in-
stalled, the water hoses and the hose clips can be laid on the
hot air pipes, which prevents frost.
In order to guarantee that the boiler is completely emp-
ty, the enclosed elbow with breather valve (fig. D: 15)
must be used for the hot water connection!
All hot water pipes should be routed in a descending
manner to the safety/drain valve! Otherwise no guar-
antee of protection from frost!
Installation of safety/drain valve
Fig. B + C
Install safety/drain valve (13) at a place which is easily accessi-
ble, near the water heater. Drill hole with 18 mm diameter and
pass through discharge socket with hose (14). Fasten safety/
drain valve with 2 screws. The draining is to be directly to the
outside (apply splash guard, if necessary).
Water pipe routing
Fig. B + C
Connect cold water supply (24) to safety/drain valve (13).
Direction of flow is unimportant.
Fig. D
Screw elbow with integrated breather valve (15) to hot water
connection pipe (upper pipe) and elbow without breather
valve (16) to cold water connecting pipe (lower pipe).
Slide on nut (17), tension ring (18) and O-ring (19). Assemble
screw connector and connecting pipe and fasten together
using nut (17).
Slide ventilation hose with 11 mm outer diameter (20) onto
the breather valve hose nozzle (21) and route towards the out-
side. Do not allow the radius of the arc to be less than 40 mm.
Cut off the ventilation hose approx. 20 mm below the floor of
the vehicle at an angle of 45° to the direction of travel.
Fig. B + C
Produce hose connection (22) for cold water supply between
safety/drain valve (13) and elbow (16 – lower pipe) on boiler.
Route the hot water pipe (23) from the elbow with integrated
breather valve (15 – upper pipe) to the hot water consumers.
Installation of the control panels
When using control panels which are specific to the ve-
hicle or the manufacturer, the electrical connection must
be established in accordance with the Truma interface descrip-
tions. Any modification made to the Truma components per-
taining to this will lead to the invalidation of the guarantee, as
well as to the exclusion of any claims for liability. The installer
(manufacturer) is responsible for providing instructions for use
for the user as well as for identification printing on the control
panels!
When selecting the location, bear in mind that the control
panels must not be subjected to direct radiant heat. Length of
connection cable 2.5 m. If required, a cable extension of 5 m
can be supplied (part no. 70000-53500).
If flush mounting is not possible, Truma will supply an
on-surface frame (25 – part no. 40000-52600) as an
accessory on request.
Fig. E
The control panel for gas operation (26) and (if provided) the
control panel for electrical operation (27) should be fitted next
to one another if at all possible (distance between centres of
holes 66 mm).
In each case, drill a hole with diameter 55 mm (distance
between centres of holes 66 mm).
Plug the control panel cable (28) to the control panel for gas
operation (26) and then fit on the rear cover cap (29) as a
stress-relieving device.
Push the cable through to the rear and lay the connection
cable (28 + 30) to the boiler.
Lay the connection cable with the orange multipole con-
nector (28) to the 12 V control electronics unit (fig. F – for
connection see “Electrical connection 12 V”).
Secure both control panels with 4 screws (31) each and fit the
cover frame (32) on them.
Truma offers side parts (32) in eight different colors for
finishing the cover frames (33) in a visually pleasing way.
Please ask your dealer.
7


Need help? Post your question in this forum.

Forumrules
1

Forum

truma-b-10

Reset search

  • When I open the drain valve,no water comes out,what is the problem,the valve Submitted on 22-6-2022 at 21:55

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Truma B 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Truma B 10 in the language / languages: English, German, Dutch, Danish, French, Italian, Spanish as an attachment in your email.

The manual is 2,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Truma B 10

Truma B 10 User Manual - English, German, Dutch, Danish, French, Italian, Spanish - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info