submerged clear water pump, near-ground suction TWP 4006 E / TWP 7506 E
Adjusting the float switch
The device comes equipped with a float switch(4) which
switches the device on or off automatically according to the
water level. Check the float switch(4) for proper functioning at
regular intervals.
Switching point Water level
TWP4006E
Height for switch-on approx. 500mm
Height for switch-off approx. 100mm
TWP7506E
Height for switch-on approx. 550mm
Height for switch-off approx. 120mm
The pumping height can be regulated by means of the float
switch(4) and its position in the float switch locking device(3).
Please observe the following information regarding the float
switch(4):
Make sure that the float switch(4) always has enough
clearance and is not permanently activated. This could
prevent the automatic switch-off causing the device to run
dry. This would damage the pump.
Make sure that the float switch(4) is able to move freely
and does not suffer from a limited mobility caused by
obstacles.
Observe a sufficient distance between float switch(4) and
float switch locking device(3), for this could prevent the
automatic switch-off causing the device to run dry.
Make sure that the position of float switch(4) is adjusted in a
way, that it does not lie flat on the ground. This could prevent
the automatic switch-off causing the device to run dry.
If required, lock the float switch(4) by means of the float switch
locking device(3). To do so, push the float switch locking
device(3) from above into the respective holder on the housing
with the float switch(4) pointing downwards. In order to adjust
the desired pumping height, insert the cable of the float
switch(4) through the float switch locking device(3).
3
4
Positioning the device
Please observe the following information regarding the device
set-up and before switching the device on:
The float switch must be able to move freely. The shaft
into which the device is lowered must not restrict the
mobility of the float switch in any way.
Do not leave the device running unattended.
Make sure that the device is firmly placed on the ground or
safely suspended.
When using the device in bodies of water with natural,
muddy ground, hook or set the device up at a slightly
elevation position, e.g. on bricks.
Check whether the hose or pipe was attached properly.
Make sure that the power cable(5) is not under tensile
load and has enough clearance.
Make sure that the mains connection corresponds to the
specifications provided in the technical data.
Check the mains socket for its proper condition. The mains
socket's fusing must be sufficient.
Make it impossible for moisture to reach mains plug or
socket. There is a risk of electric shock!
Warning of electrical voltage
Electric shock from damaged power supply cable.
Make sure not to hold or suspend the device by the
power supply cable under any circumstances.
Note
At the bottom of ponds and other waterbodies deposits
may have accumulated over time. To prevent the
device from being damaged, do not lower it all the way
to the ground unless you are certain that the water is
clean, in other words that the size of the dirt particles
in the water does not exceed 5mm.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TWP7506E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TWP7506E in the language / languages: English as an attachment in your email.

The manual is 1,83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TWP7506E

Trotec TWP7506E User Manual - German - 16 pages

Trotec TWP7506E User Manual - Dutch - 16 pages

Trotec TWP7506E User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info