756425
4
Zoom out
Zoom in
Previous page
1/18
Next page
4 EN
submerged waste water pump TWP 4036 E / TWP 7536 E / TWP 9000 ES / TWP 11000 ES
Keep in mind, that lubricants are used within the device.
These might potentially cause damages or contaminations
if emitted. Do not use the device for drinking water or in
garden ponds with either a fish population or valuable
plants.
The device is not to be carried by holding it at the power
supply cable or hose. Do not fasten it there either.
Do not place any objects on the device – not even to
weight it down. The device will sink to the ground due to
its own weight.
After the set-up of the device, its mains plug must be
readily accessible during operation.
Wear sturdy shoes to protect yourself against electric
shock.
Provide appropriate frost protection.
Before taking the device into operation, have the following
checked by an expert:
earthing, neutral conductor and RCD must be
functioning properly and correspond to the national
regulations,
electrical plug connections must be protected from
moisture.
Intended use
The device is only suited for draining, conveying and pumping
over the following media:
clear water and waste water
non-corrosive suds (e.g. leaking washing machine)
slightly chlorinated water
When doing so, the water must not contain any suspended
matter exceeding a maximum particle size of 25mm.
The device is fully submersible (watertight encapsulation) and
can be immersed up to 7m into the pumping medium.
The water temperature must not exceed 35°C.
The device may temporarily be used for e.g.:
pumping out flooded basements
emptying tanks and containers
water withdrawal from wells and shafts
Improper use
The device is not suitable for continuous operation (e.g. as
recirculation pump for ponds).
Using the device in swimming pools and the like is
prohibited.
The device is not suitable as permanent, automatic
overflow protection of e.g. wells or fountains or for the
regulation of the groundwater level. Use a stationary waste
water pumping system for building and property drainage
for these purposes.
The device is not suitable for increasing the pressure of
existing water supply networks.
The device is not suitable for pumping potable water.
The device must not be used for aggressive, abrasive,
caustic, corrosive, combustible or explosive pumping
media, e.g.:
brine
sandy water
food
cleaning agents
fuels (e.g. petrol, diesel)
oils
greases
petroleum
nitro-cellulose thinner
waste water from lavatories and urinal installations
The device must not be used at freezing temperatures.
Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
Personnel qualifications
People who use this device must:
be aware of the dangers that occur when working with
electric devices in damp areas.
have read and understood the operating manual, especially
the Safety chapter.
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
Warning of electrical voltage
Information marked with this symbol indicates dangers
to the life and health of persons due to electrical
voltage.
General warning sign
This symbol indicates that you must be aware of the
dangers that can occur when working with the device.
Device may start up without warning
This symbol indicates that the device may start up
without warning when it is switched on.
Do not use damaged power cables or mains plugs
This symbol indicates that the device must no longer be
operated if the power cable is damaged.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TWP11000ES at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TWP11000ES in the language / languages: English as an attachment in your email.

The manual is 2,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TWP11000ES

Trotec TWP11000ES User Manual - German - 19 pages

Trotec TWP11000ES User Manual - Dutch - 19 pages

Trotec TWP11000ES User Manual - French - 19 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info