726477
8
Zoom out
Zoom in
Previous page
1/12
Next page
8 EN
dehumidifier TTP 5 E / TTP 10 E
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
Warning of electrical voltage
Do not remove the condensation tank from the device
during operation.
The device keeps running even if the condensation
tank is not inserted!
Otherwise, water may drop from the device
uncontrollably and damage the device. There is a risk
of electric shock!
1. Press the on/off switch(1).
ð The indicator LED(10) is illuminated in green.
ð The fan switches on.
ð The device starts to dehumidify.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Empty the condensation tank, if need be.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damage.
Check the on-site fusing.
Check the condensation tank for correct seating.
Check whether the condensation tank is full. The indicator
LED(10) is illuminated in orange.
Check the room temperature. Observe the device's
permissible ambient temperature according to the
technical data.
Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but there is no formation of
condensate:
Check the float in the condensation tank for dirt.
If necessary, clean the condensation tank. The float must
be able to move freely.
Check the room temperature. Observe the device's
permissible ambient temperature according to the
technical data.
Ensure that the relative room humidity complies with the
technical data.
Check the air filter for dirt. If necessary, clean or replace
the air filter.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
Check the device for leaks.
The device gets very warm, is loud or loses power:
Check the air inlets and air filters for dirt. Remove external
dirt.
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company or by Trotec.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TTP 5 E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TTP 5 E in the language / languages: English as an attachment in your email.

The manual is 2,7 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TTP 5 E

Trotec TTP 5 E User Manual - English - 12 pages

Trotec TTP 5 E User Manual - German - 13 pages

Trotec TTP 5 E User Manual - Dutch - 12 pages

Trotec TTP 5 E User Manual - Danish - 13 pages

Trotec TTP 5 E User Manual - French - 13 pages

Trotec TTP 5 E User Manual - Italian - 13 pages

Trotec TTP 5 E User Manual - Polish - 13 pages

Trotec TTP 5 E User Manual - Portuguese - 13 pages

Trotec TTP 5 E User Manual - Swedish - 13 pages

Trotec TTP 5 E User Manual - Turkish - 13 pages

Trotec TTP 5 E User Manual - Spanish - 13 pages

Trotec TTP 5 E User Manual - Norwegian - 13 pages

Trotec TTP 5 E User Manual - Finnish - 13 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info