dehumidifier TTK 96 E / TTK 127 E
The device is running, but there is no formation of
condensate:
Check the float in the condensation tank for dirt.
If necessary, clean the condensation tank. The float must
be able to move freely.
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
Ensure that the relative room humidity complies with the
technical data.
Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
Check the air filter for dirt. If necessary, clean or replace
the air filter.
Check whether the device is running in comfort mode.
In this case, the compressor switches off automatically
once the relative room humidity is below 45%.
From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device is loud or vibrates:
Check whether the device is set up in a stable and upright
position.
Condensate is leaking:
Check the device for leaks.
The compressor does not start:
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
Ensure that the relative room humidity complies with the
technical data.
Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
Check whether the device is running in comfort mode.
In this case, the compressor switches off automatically
once the relative room humidity is below 45%.
Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10minutes before
reconnecting it.
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or loses power:
Check the air inlets and air filters for dirt. Remove external
dirt.
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and
air-conditioning or by Trotec.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Error codes
The following error codes can be displayed:
Error code Cause Remedy
AS Error humidity sensor Disconnect the device
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.
ES Error at the
temperature sensor
of the evaporator
Disconnect the device
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.
P2 Condensation tank
full or not inserted
correctly
Empty the condensation
tank or check the
condensation tank for
correct fit.
EC Leakage in the
refrigerant circuit
Switch the device off and
contact the customer
service. Also see the
information regarding the
refrigerant circuit in chapter
Maintenance.
E3 General fault at the
device
Disconnect the device
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TTK96E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TTK96E in the language / languages: English as an attachment in your email.

The manual is 5,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TTK96E

Trotec TTK96E User Manual - German - 24 pages

Trotec TTK96E User Manual - Dutch - 24 pages

Trotec TTK96E User Manual - French - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info