dehumidifier TTK 67 E / TTK 68 E / TTK 73 E
Safety warnings for devices containing flammable
refrigerants
Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
Please note that the refrigerant is odourless.
Only install the device in compliance with the national
installation regulations.
Observe the national gas regulations.
Only install, operate and store the device TTK 67 E/
TTK 68 E / TTK 73 E in a room measuring more than 4m2.
Store the device in a way that no mechanical damage can
occur.
Please note that the connected pipelines must not contain
any sources of ignition.
R290 is a refrigerant that complies with European
environmental regulations. No part of the cooling circuit
may be perforated.
Observe the maximum refrigerant capacity in the technical
data.
Do not drill through or burn.
Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.
Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.
Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.
Unventilated rooms, in which the device is installed,
operated or stored, must be built in a way to ensure that
potentially leaking refrigerant cannot accumulate. This
serves to avoid fire or explosion hazards resulting from an
ignition of the refrigerant by an electric furnace, cooking
stove or another ignition source.
The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
Intended use
Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry.
Intended use comprises:
dehumidifying and drying:
living rooms, bedrooms, bathrooms and basements
laundries, holiday homes, camper vans, boats
maintaining the dryness of:
storage spaces, archives, laboratories, garages
bathrooms, wash rooms, changing rooms etc.
Foreseeable misuse
The device is not intended for industrial use.
Do not place the device on wet or flooded ground.
Do not place any objects, e.g. clothing, on the device.
Do not use the device outdoors.
Do not make any unauthorised modifications, alterations or
structural changes to the device.
Any use other than the intended use is regarded as a
reasonably foreseeable misuse.
Personnel qualifications
People who use this device must:
be aware of the dangers that occur when working with
electric devices in damp areas.
have read and understood the operating manual, especially
the Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TTK67E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TTK67E in the language / languages: English as an attachment in your email.

The manual is 10,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TTK67E

Trotec TTK67E User Manual - German - 28 pages

Trotec TTK67E User Manual - Dutch - 29 pages

Trotec TTK67E User Manual - French - 29 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info