726872
8
Zoom out
Zoom in
Previous page
1/23
Next page
8 EN
dehumidifier TTK 54 E / TTK 66 E
Operation
Notes:
Avoid open doors and windows.
After being switched on, the device operates fully
automatically.
The fan permanently runs in dehumidification mode even
after the set nominal value has been reached until the
device is switched off.
Operating elements
10 11 12 13 14
1718
16
1920212223
15
No. Designation Meaning
10 TIMER LED Illuminated when the timer is
activated
11 Fan speed LEDs Fan speed indication:
Low
Med(ium)
High (low + med.)
12 Full LED Condensation tank full or not
inserted correctly
13 Dryer LED Laundry drying mode is enabled
14 Cont. LED Continuous operation is enabled
15 Comfort LED Comfort mode is enabled
16 Power LED Illuminated during operation
17 ON/OFF button Power button:
Switching the device on or off
18 MODEbutton Selection button for operating
modes:
Dehumidification (not indicated)
Dryer = laundry drying function
Cont. = continuous operation
Comfort = comfort mode
19 Increase value button Setting the relative room
humidity
Setting the number of hours for
the timer function
No. Designation Meaning
20 Segment display Indication of the current relative
room humidity level
Indication of the relative room
humidity level during set-up
Indication of the number of
hours during timer
programming
Display of error codes
21 Decrease value button Setting the relative room
humidity
Setting the number of hours for
the timer function
22 FAN button Setting high, medium or low fan
speed
23 TIMER button Switches the timer function on
or off
Info
An acoustic signal is emitted each time a setting is
activated.
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Press the ON/OFF button(17).
ð The device starts in dehumidification mode.
Setting the operating mode
Dehumidification
Continuous operation
Comfort mode
Laundry drying function
Dehumidification
The device keeps running until reaching the desired relative
room humidity. Then the compressor switches off and the fan
keeps running. Once the desired relative room humidity is
exceeded, the compressor switches back on.
In this operating mode, the desired relative room humidity can
be set at any time in increments of 5% within a setting range of
35% to 85%.
1. Press the MODE button(18) until only the Power LED(16)
is lit.
2. Press the Increase value(19) or Decrease value button(21)
to select the relative room humidity.
ð The desired relative room humidity is indicated in the
segment display(20) for approx.5seconds. Then the
current relative room humidity is displayed again.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TTK54E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TTK54E in the language / languages: English as an attachment in your email.

The manual is 3,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TTK54E

Trotec TTK54E User Manual - German - 23 pages

Trotec TTK54E User Manual - Dutch - 24 pages

Trotec TTK54E User Manual - Danish - 23 pages

Trotec TTK54E User Manual - French - 26 pages

Trotec TTK54E User Manual - Italian - 25 pages

Trotec TTK54E User Manual - Polish - 26 pages

Trotec TTK54E User Manual - Portuguese - 25 pages

Trotec TTK54E User Manual - Swedish - 24 pages

Trotec TTK54E User Manual - Turkish - 26 pages

Trotec TTK54E User Manual - Spanish - 25 pages

Trotec TTK54E User Manual - Norwegian - 24 pages

Trotec TTK54E User Manual - Finnish - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info