dehumidifier TTK 29 E / TTK 51 E / TTK 70 E
The compressor does not start:
Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5°C).
Ensure that the relative room humidity complies with the
technical data.
Check the preselected relative room humidity. The
humidity in the room must be above the selected range.
Check whether the device is running in comfort mode. In
this case, the compressor switches off automatically once
the relative room humidity is below 50%.
Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10minutes before
reconnecting it.
The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.
The device gets very warm, is loud or loses power:
Check the air inlets and air filters for dirt. Remove external
dirt.
From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Error codes
The following error messages can be displayed on the segment
display(7):
Error code Cause Remedy
E1 Short circuit at the
temperature sensor
and printed circuit
board.
Please contact the
customer service.
E2 Short circuit between
the copper tube of
the temperature
sensor and the
PCBwiring.
Please contact the
customer service.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TTK29E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TTK29E in the language / languages: English as an attachment in your email.

The manual is 3,21 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TTK29E

Trotec TTK29E User Manual - German - 25 pages

Trotec TTK29E User Manual - Dutch - 25 pages

Trotec TTK29E User Manual - Danish - 25 pages

Trotec TTK29E User Manual - French - 26 pages

Trotec TTK29E User Manual - Italian - 26 pages

Trotec TTK29E User Manual - Polish - 25 pages

Trotec TTK29E User Manual - Portuguese - 25 pages

Trotec TTK29E User Manual - Swedish - 25 pages

Trotec TTK29E User Manual - Turkish - 25 pages

Trotec TTK29E User Manual - Spanish - 25 pages

Trotec TTK29E User Manual - Norwegian - 25 pages

Trotec TTK29E User Manual - Finnish - 25 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info