580095
21
Zoom out
Zoom in
Previous page
1/105
Next page
EN Operating Manual – Construction dryer TTK 1500 B - 3
Technical data
Power consumption
The device's power consumption depends on the current room
temperature and relative humidity.
Multiply the operating hours (see operating hours counter (12)) by
a consumption value of one kilowatt per hour to determine the
approximate power consumption.
To determine the precise power consumption, a separate energy
cost gauge can be set between the construction dryer and the
power source. Contact TROTEC
®
customer service if you want this
alternative version.
Parameters Values
Model TTK 1500
Dehumidifying capacity, max. 400 l / 24 h
Dehumidifying capacity (20 °C / 60 % relative humidity) 100 l / 24 h
Suitable for room dimensions up to:
construction drying or clearing water damages
maintaining dryness
1700 m³
3400 m³
Operating temperature 0-40 °C
Working range for relative humidity 35-100 %
Volume of airflow, max. 2200 m³/h
Electric connection 400 V / 50 Hz / 6.75 A
Power consumption, max. 2.7 kW
Power consumption, average 1.7 kW
Fuse (home) 10 A
Compressor Reciprocating
Refrigerant R407c
Amount of refrigerant 2.5 kg
Weight 141 kg
Dimensions (HxDxW) 660 x 660 x 1313 mm
Minimum distance from walls of other objects A: Above: 50 cm
B: Behind: 50 cm
C: Side: 50 cm
D: Front: 50 cm
Sound pressure level LpA (3 m; complies with DIN 45635-01-KL3) 58 dB(A)
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TTK 1500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TTK 1500 in the language / languages: English, German, Dutch, French, Italian, Turkish as an attachment in your email.

The manual is 3,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info