727850
9
Zoom out
Zoom in
Previous page
1/15
Next page
EN 9
oil-filled radiator TRH 20 E / TRH 21 E / TRH 22 E / TRH 23 E
No. Designation
8 rotary switch room thermostat
9 rotary switch for heating level selection
TRH 20 E/ TRH 22 E
level1: 800 W
level2: 1,200W
level3: 2,000W
TRH 21 E/ TRH 23 E
level1: 1000W
level2: 1,500W
level3: 2,500W
10 operating control lamp
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
Info
The device will not be switched on until the room
temperature falls below the temperature set at the
room thermostat.
Setting the heating level
1. Set the rotary switch for heating level selection(9) to the
desired heating level.
Setting the room thermostat
1. Select the desired temperature via the infinitely variable
rotary switch(8) of the room thermostat.
ð When the room thermostat is switched on the operating
control lamp(10) will be illuminated.
ð After approx. 10min the deviceTRH 20 E/ TRH 22 E
will have reached the set heat output.
ð After approx. 8min the deviceTRH 21 E/ TRH 23 E will
have reached the set heat output.
To find the ideal thermostat setting, please proceed as follows:
Set the thermostat control to maximum.
As soon as the desired temperature has been reached,
slowly turn the thermostat control back until the operating
control lamp(10) goes out.
The device now automatically maintains the desired
temperature level.
The room thermostat controls the room temperature
automatically:
Upon reaching the set value in heating level2 and3 the
device reduces its heating performance to level1.
When falling below the set value, the heating will
automatically switch back over to level2 or level3.
When the device is set to heating level1, the room temperature
will not be controlled automatically.
Frost monitor function:
1. Set the heating level to level1.
2. Turn the rotary switch for the room thermostat(8) to a
position just above-. In this position, the room thermostat
switches on the heating automatically if the room
temperature drops below the frost protection temperature.
Switching on the turbo blower (TRH 22 E/ TRH 23 E)
1. Set the flip switch for the blower(7) toI.
ð The lamp at the flip switch will be illuminated.
ð The blower will start to run when the device produces
heat.
ð The blower will turn off when the room thermostat
switches off the heating.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Set both rotary switches(8, 9) to position0 or-.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Allow the device to cool down completely.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TRH20E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TRH20E in the language / languages: English as an attachment in your email.

The manual is 1,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TRH20E

Trotec TRH20E User Manual - German - 15 pages

Trotec TRH20E User Manual - Dutch - 15 pages

Trotec TRH20E User Manual - French - 15 pages

Trotec TRH20E User Manual - Italian - 15 pages

Trotec TRH20E User Manual - Polish - 15 pages

Trotec TRH20E User Manual - Turkish - 14 pages

Trotec TRH20E User Manual - Spanish - 15 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info