756430
4
Zoom out
Zoom in
Previous page
1/19
Next page
4 EN
garden pump TGP 1025 E / TGP 1025 ES / TGP 1025 ES ES
Before taking the device into operation, have the following
checked by an expert:
earthing, neutral conductor and RCD must be
functioning properly and correspond to the national
regulations,
electrical plug connections must be protected from
moisture.
Provide appropriate frost protection.
Never operate the device in the rain. Keep the device away
from environmental influences such as wet conditions or
frost. In particular, keep the electrical connections dry and
make sure they are located in a flood-proof area.
Never operate the device when dry or with the suction line
closed. The intake opening of the suction line must always
be submerged in the pumping medium.
Do not use the device at freezing temperatures or
temperatures above 40°C.
Do not pump any contaminated media or liquids with a
temperature of more than 35°C. Pumping contaminated
media can cause damage to the inside of the device.
Do not under any circumstances pump brine, aggressive
liquids (alkalis, acids, etc.), combustible or explosive
liquids (petroleum, petrol, etc.) or food (drinking water,
etc.).
Risk of injury due to hot water. The water inside the device
can heat up during operation and cause injuries.
Check the device for damage at regular intervals prior to
use. Pay particular attention to the mains cable and plug.
In the event of damage or functional restrictions, the
device must no longer be used until it has been repaired by
an expert. Only original spare parts may be used for this
purpose.
Do not use the device for drinking water supply, and do not
integrate it into the drinking water circuit. In addition,
please observe the local regulations of the water and
wastewater authorities.
Intended use
The device is designed for pumping clear water serving as
service water in the home and garden.
The device can be applied for the following pumping media:
well water
rain water from rain barrels or cisterns
water from ponds and streams (with an appropriate pre-
filter)
The device is suitable for the following fields of application:
watering gardens and vegetable beds
operating lawn sprinklers
service water supply in the home and garden
The water temperature must not exceed 35°C.
Improper use
The device is not suitable for continuous operation (e.g. as
recirculation pump for ponds).
Using the device in swimming pools and the like is
prohibited.
The device is not suitable for increasing the pressure of
existing water supply networks.
The device is not suitable for pumping potable water.
The device must not be used for aggressive, abrasive,
caustic, corrosive, combustible or explosive pumping
media, e.g.:
brine
sandy water
food
cleaning agents
fuels (e.g. petrol, diesel)
oils
greases
petroleum
nitro-cellulose thinner
waste water from lavatories and urinal installations
The device must not be used at freezing temperatures.
Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
Personnel qualifications
People who use this device must:
be aware of the dangers that occur when working with
electric devices in damp areas.
have read and understood the instructions, especially the
Safety chapter.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TGP1025ES at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TGP1025ES in the language / languages: English as an attachment in your email.

The manual is 1,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TGP1025ES

Trotec TGP1025ES User Manual - German - 20 pages

Trotec TGP1025ES User Manual - Dutch - 20 pages

Trotec TGP1025ES User Manual - French - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info