8 EN
convector TCH 20 E / TCH 22 E
Programming the timer (TCH22E only)
The timer has a 24-hour format. You can use it to determine
time intervals during which the device shall be switched on.
The timer has a three-step control (12):
Position 0: The device is switched off.
Position I: Continuous operation.
Centre position (clock symbol): The heating is switched on
and off by the programmed timer.
To program the timer, proceed as follows:
1. Turn the timer (9) clockwise until the indicator (11) points
to the current time.
2. Slide the segments (10) for the time intervals during which
the device shall be switched on outwards.
3. Set the control (12) to centre position.
ð The timer is programmed.
Info
Please note that if the timer is activated, the device will
switch on and run unattended. Take the necessary
precautions. For instance, do not leave children
unattended near the device.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Set all flip switches to Off. The lamps at the flip switches
turn off.
When using the optional timer:
Set the timer control (12) to 0.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Allow the device to cool down completely.
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
Errors and faults
Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damages.
Check the on-site fusing.
Check the room temperature. The room thermostat may
have switched off, because the desired room temperature
has been reached.
The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.
Check the timer (TCH 22 E only): If the control is set to 0 or
if the current time has not been selected, the device will
not start. Set the control to I (continuous operation).
Check whether the overheating protection has tripped, see
chapter Safety.
Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The fan is not running (TCH 22 E only):
Check whether the device is switched on.
Check the power connection.
Check the power cable and mains plug for damages.
The fan motor might be defective. Have a defective fan
motor replaced by a specialist electrical company.
The air current is reduced:
Check the air inlet and outlet. Make sure that air inlet and
outlet are not obstructed. Remove any dirt. Observe the
minimum distance from walls or other objects according to
the technical data.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TCH20E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TCH20E in the language / languages: English as an attachment in your email.

The manual is 0,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TCH20E

Trotec TCH20E User Manual - German - 12 pages

Trotec TCH20E User Manual - French - 12 pages

Trotec TCH20E User Manual - Italian - 12 pages

Trotec TCH20E User Manual - Turkish - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info