EN Operating Manual – Air Cleaner TAC 1500 / TAC 3000 6
When putting up the device, position it in the room's centre
the air of which is to be cleaned. Alternatively, you can also
position the device near the source of air contamination.
Prior to operation you have to ensure that the filters have
been installed in the device as desired.
Also check, whether the pressure sensors are connected cor-
rectly. If the device, during operation, emits a warning of a fil-
ter being spent, the respective filter has to be replaced.
Put the device up in a level, upright and stable position.
Do not create tripping hazards when laying the power cable
or other electrical cables.
Ensure that extension cords are completely unrolled.
Installation of the device in the room, the air of which is
to be purified
The device works in recirculation mode, this means that the
contaminated air enters the air cleaner via the air inlet and is
blown out through the air outlet in purified state.
Fig. 8 Air purification in sealed off area via air circulation
Installation of the device outside of the room, the air of
which is to be purified
The device can be connected in either recirculation or ventilation
mode.
In recirculation mode, the air to be cleaned is led via a hose
from the room into the air inlet of the device. The purified air
is fed through another hose from the air outlet and back into
the room.
In ventilation mode, the air to be cleaned is led via a hose
from the room into the air inlet of the device. This creates a
slight negative pressure in the room. Clean, fresh air flows in
from outside.
Fig. 9 Installation variants for maintaining the pressure
When connecting pipes or hoses,
the following is to be observed:
The used pipes and hoses must be designed for the available
static compression of the fans. They should preferably be laid
in a straight line and at full length. 7.6 m of air hose each can
be connected to both the TAC 1500's air inlet and outlet.
To prevent an immediate neutralization of the air flows, air in-
let and air outlet should be positioned at a distance of at least
1 m from one another.
Control panel
Fig. 10 Control panel
Switch-on
Switch the device on by actuating the mains switch (1). En-
sure that air inlet and outlet are not covered. The integrated
indicator light lights up.
Switch-off
Switch the device off by actuating the mains switch (1). The
integrated indicator light goes off.
Operation
No. Designation
1 mains switch
2 fan speed controller
3 filter indication pre-filter (coarse particulate air filter G4
& fine particulate air filter F7)
4 filter indication high-efficiency particulate air filter
(HEPA H13)
H
E
P
A
F
I
L
T
E
R
F
E
I
N
F
I
L
T
E
R
1
2
3
4
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec TAC 3000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec TAC 3000 in the language / languages: English as an attachment in your email.

The manual is 1,97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec TAC 3000

Trotec TAC 3000 User Manual - German - 14 pages

Trotec TAC 3000 User Manual - Dutch - 17 pages

Trotec TAC 3000 User Manual - French - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info