Error codes
Error messages
When the Alarm LED lights up, the following error messages
might be displayed:
Message Cause Troubleshooting
PunP
The internal pump alarm is activated. Empty the pump container (e.g. by means of a suction pump), then
check whether the pump operates properly again. The alarm stops as
soon as the water has been completely drained from the pump
container.
LOPS
The air filter might be contaminated. Check the air filter for dirt. If required, clean the air filter (see chapter
Maintenance).
When the fault has been eliminated, disconnect the mains plug and
plug it back in after 5s to reset the alarm.
There might be a leak in the internal
refrigerant circuit.
Have the device checked by a specialist company for cooling and air-
conditioning.
When the fault has been eliminated, disconnect the mains plug and
plug it back in after 5s to reset the alarm.
HIPS
Plug connections at the external
cooling circuit do not fit properly.
The pump of the external cooling
circuit is not operating properly.
The fan of the external heat exchanger
does not operate.
The device might not be operating due
to excessive ambient temperatures.
There is insufficient water in the
cooling circuit between the basic
device and the external unit.
Check the plug connections at the external heat exchanger.
Check the pump. If necessary, have the pump checked by a specialist
company for cooling and air-conditioning.
Check the fan. If necessary, have the fan checked by a specialist
company for cooling and air-conditioning.
Check the outside temperature (temperatures above 35°C can be
critical).
After the inspection press the RESET button(33).
Disconnect the mains plug and plug it back in after 5s to reset the
alarm.
Check whether there is sufficient water in the tank(5).
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec PT15000S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec PT15000S in the language / languages: English as an attachment in your email.

The manual is 1,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec PT15000S

Trotec PT15000S User Manual - German - 26 pages

Trotec PT15000S User Manual - Dutch - 26 pages

Trotec PT15000S User Manual - French - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info