728014
10
Zoom out
Zoom in
Previous page
1/21
Next page
10 EN
air cooler PAE 51
Operation
Avoid open doors and windows.
Operating elements
17 18 19
20
21
22
23
24
25
262728
29
30
No. Designation Meaning
17 Cooling/
Humidification button
Switching the air cooling mode on
or off
18 Cooling/
Humidification LED
Illuminated when air cooling mode
is activated
19 Hours LEDs Indication of the number of hours
of the activated timer 1h, 2h, 4h
and 8h
20 Ventilation LED Illuminated when ventilation mode
is activated
21 Air freshening LED Illuminated when air freshening
mode is activated
22 Night mode LED Illuminated when night mode is
activated
23 Mode button Selection button for ventilation, air
freshening and night mode
24 Timer button Switching the timer on or off
25 Speed button Setting the fan speed and the filter
drying function
26 Fan stage LEDs
I
II
III
Fan speed indication is
illuminated:
Silent stage = ultra-silent
operation
Stage 1 = low
Stage 2 = medium
Stage 3 = high
27 On / Off LED Illuminated during operation
28 Oscillation LED Illuminated when swing function
is activated
29 On / Off button Switching the device on or off
30 Oscillation button Switching the swing function on
or off
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
1. Press the On / Off button(29).
ð The device starts in ventilation mode at fan stageII.
ð The LEDs On/ Off(27), Ventilation(20) and Fan stageII(26)
are illuminated.
Setting the operating mode
The device comes with the following operating modes:
air cooling
ventilation
air freshening
night mode
Air cooling
The air cooling mode can be switched on in addition during all
other operating modes.
During air cooling the pump is switched on and the water is
distributed over the honeycomb filter to cool the circulating air.
If the water tank is empty, an acoustic signal will be emitted.
Please proceed as follows to activate air cooling:
1. Press the Cooling/ Humidification button(17).
ð The Cooling/ Humidification LED(18) is illuminated.
ð The pump starts.
2. Press the Speed button(25) to set the desired fan stage
(Silent and 1 to3).
3. Press the Cooling/ Humidification button(17) again to
switch air cooling off.
ð The Cooling/ Humidification LED(18) goes out.
ð The device continues to run in the previously selected
operating mode.
Note
When air cooling mode is activated, the air and
honeycomb filter must not be removed, otherwise the
water from the filter will drip down into the device.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec PAE51 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec PAE51 in the language / languages: English as an attachment in your email.

The manual is 2,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec PAE51

Trotec PAE51 User Manual - German - 21 pages

Trotec PAE51 User Manual - Dutch - 21 pages

Trotec PAE51 User Manual - French - 21 pages

Trotec PAE51 User Manual - Italian - 21 pages

Trotec PAE51 User Manual - Polish - 21 pages

Trotec PAE51 User Manual - Turkish - 20 pages

Trotec PAE51 User Manual - Spanish - 21 pages

Trotec PAE51 User Manual - Finnish - 21 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info