689394
11
Zoom out
Zoom in
Previous page
1/17
Next page
EN 11
air cooler PAE 25
4. Refit the water tank into the device.
5. Make sure that the device is neither damp nor wet on the
outside. Otherwise wipe it dry.
6. Plug the power cable back into the mains socket.
7. Switch the device on.
ð The air cooling symbol(19) no longer flashes.
Auto stop function
If the water tank is empty or not inserted correctly, an acoustic
signal signal will be emitted three times and the air cooling
symbol(19) will flash.
In air cooling mode, the fan continues running; in air freshening
mode, the device will stop automatically after a while.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switch off the device.
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Empty and clean the water tank (see chapter
Maintenance).
Clean the device according to the Maintenance chapter.
Store the device according to the Storage chapter.
Available accessories
Designation Article number
Evaporation filter 7.710.000.837
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
Check the power connection.
Check the power cable and mains plug for damage.
Check the on-site fusing.
Wait for 10minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device works with reduced or no capacity:
Check the position of the horizontal ventilation flaps. They
should be opened to the maximum.
Check the air filter for dirt. If necessary, clean or replace
the air filter.
Check the minimum distance to walls or other objects.
Position the device a little more in the room's centre if
required.
The device is running, but there is no air cooling or pump
operation:
Check whether air cooling mode is activated. The air
cooling symbol(19) should be illuminated.
Check the filling level of the water tank (see chapter Filling
the water tank). The air cooling symbol(19) should not
flash.
Check whether there are any objects blocking the pump
inlet. Make sure that the pump inlet is not blocked.
In case the pump does not operate despite a correctly filled
water tank and activated air cooling mode, the pump might
be defective. Please contact the customer service.
Water is leaking:
Check the device for leaks.
Check the water tank for tight fit.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec PAE 25 Aircooler at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec PAE 25 Aircooler in the language / languages: English as an attachment in your email.

The manual is 2,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec PAE 25 Aircooler

Trotec PAE 25 Aircooler User Manual - German - 17 pages

Trotec PAE 25 Aircooler User Manual - Dutch - 18 pages

Trotec PAE 25 Aircooler User Manual - French - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info