12 EN
local air conditioner PAC 3550 PRO
Remote control
All settings of the device can also be made using the remote
control included in the scope of delivery.
Insert suitable batteries in the remote control (seechapter
Technical annex).
Info
After a longer period of non-use, the remote control
will switch to standby mode. Standby mode can be
terminated by pressing the POWER button on the
remote control Please note that the device
automatically takes over the current settings from the
remote control.
Cool Fan Dry
Heat
Timer
°C
°F
Hr
Auto
Swing
TIMER SWING °C °F
UP
FAN
POWER
MODE
DOWN
18
29
30
23
28
35
34
19
24
21
31
20
22
26
32
No. Designation Meaning
18 TIMER button Automatic switch-on timer
function in increments of 1hour
(1h to 24h)
Automatic switch-off timer
function in increments of 1hour
(1h to 24h)
19 FAN button Setting the fan speed in 3stages:
High, Medium and Low
Only enabled in cooling and
ventilation mode.
20 UP button Increasing the target temperature
(17°C to 30°C) or
the number of hours of the timer
(1h to 24h).
21 Segment display Display of current room
temperature when in operation
Display of target temperature
while setting it
Display of timer
Display of error codes
22 DOWNbutton Decreasing the target temperature
(17°C to 30°C) or
the number of hours of the timer
(1h to 24h).
No. Designation Meaning
23 MODE button Selection button for the mode of
operation
cooling
ventilation
dehumidification
24 POWER button Power button:
Switching the device on or off
26 Timer indication Timer active
28 Battery indication Charging status of the batteries
for the remote control
29 Operating mode
indication
Cool= cooling
Fan= ventilation
Dry= dehumidification
30 Fan speed indication Low =
Medium =
High =
31 °C / °F button Switching temperature indication
between °C and °F
32 SWING button Adjusting the position of the
ventilation flaps
34 Transmission
indication
Indicates transmission to the
device when the button is pressed
35 Remote control
transmitter/ receiver
Communication between device
and remote control
Changing the unit °C / °F
The temperature in the segment display(21) can be indicated in
°C or °F.
Please proceed as follows to change the temperature unit:
1. Simultaneously press the increase value(20) and decrease
value(22) buttons.
Alternatively, you can press the °C/ °F button(31) on the
remote control.
ð The displayed temperature is converted to the other unit.
Swing function
The swing function can only be activated via the remote control.
Using the swing function, you can adjust the position of the
ventilation flaps or activate continuous movement of the
ventilation flaps.
1. Press the SWING button(32).
ð The ventilation flaps move up and down continuously.
ð The swing function indication(36) is illuminated.
2. Press the SWING button(32) again to stop the ventilation
flaps in a certain position and to switch off the swing
function.
ð The swing function indication(36) disappears.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec PAC3550PRO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec PAC3550PRO in the language / languages: English as an attachment in your email.

The manual is 1,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec PAC3550PRO

Trotec PAC3550PRO User Manual - German - 20 pages

Trotec PAC3550PRO User Manual - Dutch - 22 pages

Trotec PAC3550PRO User Manual - French - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info