local air conditioner PAC 3500 SH
3. Connect the condensation drain hose to the upper(6) or
lower hose connection(8).
4. Guide the other hose end to a suitable drain or sufficiently
dimensioned collection container. To ensure that the
condensate can run off, the condensation drain hose must
not be kinked, nor should it have to overcome an uphill
incline towards the drain.
ð For heating operation, use the adapter for the
condensation drain hose at the end of the hose.
Ventilation
Info
Remove the exhaust air hose during ventilation.
In ventilation mode the room air is circulated, but not cooled.
1. Press the Mode button(26) until the ventilation LED(14) is
illuminated.
ð Ventilation mode is selected.
ð The current room temperature is indicated on the
segment display(16).
2. Press the Fan speed button(23) to set the desired fan
stage.
ð The fan speed LED(19) indicates the selected fan stage.
When the automatic stage is activated, none of the fan
speed LEDs(19) is illuminated.
Setting the timer
The timer has two modes of operation:
automatic switch-on upon expiry of a preset number of
hours.
automatic switch-off upon expiry of a preset number of
hours.
This setting can be made at the device or using the remote
control.
Automatic switch-on and automatic switch-off may be enabled
at the same time. The timer LEDs(13) on the control panel will
then be illuminated simultaneously. When using the remote
control for setting, TIMER ON and TIMER OFF(42) will
additionally be indicated on the display(29) simultaneously.
The function can be set in all operating modes and also during
stand-by.
The number of hours can be set in increments of 0.5hours
(0.5h to 10h) or in increments of 1hour (10h to 24h).
Note
Do not leave the operating device unattended in a
freely accessible room with an activated timer.
Automatic switch-on
ü The device is switched off.
1. Press the Timer button(27) until the timeron LED(13) is
illuminated.
2. Set the desired number of hours by use of the Increase
value(24) and Decrease value(25) buttons.
ð The number of hours will be indicated on the segment
display(16) for approx. 5s.
ð The timer setting equals the desired number of hours.
ð After the predefined time, the device switches itself on.
Notes regarding automatic switch-on:
If the device is disconnected from the power supply, all
settings for automatic switch-on are deleted.
Manually switching the device on disables the automatic
switch-on function.
If you select 0.0hours, the timer will be off.
Automatic switch-off
ü The device is switched on.
1. Press the Timer button(27) until the timeroff LED(13) is
illuminated.
2. Set the desired number of hours by use of the Increase
value(24) and Decrease value(25) buttons.
ð The number of hours will be indicated on the segment
display(16) for approx. 5s.
ð The timer setting equals the desired number of hours.
ð After the predefined time, the device switches itself off.
Notes regarding automatic switch-off:
Pressing the On/Off button(21) deactivates the automatic
switch-off function.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec PAC3500SH at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec PAC3500SH in the language / languages: English as an attachment in your email.

The manual is 2,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec PAC3500SH

Trotec PAC3500SH User Manual - German - 24 pages

Trotec PAC3500SH User Manual - Dutch - 24 pages

Trotec PAC3500SH User Manual - French - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info