7 Operating manual – Local air conditioner PAC 2000 X EN
Setting the operating mode
To set the operating mode, press the Functions button (2):
–cooling,
–heating,
dehumidifying (drying).
Setting the temperature
Use the temperature control buttons (+ (3) or - (4)) to set the
desired temperature.
Setting the fan speed
Choose from the available speed levels by pressing the
button Speed (6).
–Low
–Medium
–High
–Auto
Note:
During dehumidification operation this button is disabled, since in
dehumidification mode the device can only be operated at low fan
speed.
If AUTO is selected during cooling operation, the device
automatically switches between the other three speed levels –
depending on the temperature difference between the set and the
actual ambient temperature.
Setting the timer
Timer on
TIMER ON is used to turn the device on automatically after the set
time has passed.
Press the TIMER button (7) in stand-by to set the desired
time.
Once the set number of hours has lapsed, the device will
switch on automatically.
If you press the POWER button (1) before the time has
expired, the device will switch on and the set time will be
deleted.
You can also determine the function and fan speed while
setting the timer.
Timer off
TIMER OFF is used to turn the device off automatically after the
set time has passed.
Press the TIMER button (7) during operation to set the desired
time.
Once the set number of hours has lapsed, the device will
switch off automatically.
If you press the POWER button (1) before the time has
expired, the device will switch off and the set time will be
deleted.
Sleep control function
Note:
The sleep control function is only available in cooling mode.
Press the SLEEP button (8) during cooling operation to set the
temperature. After one hour the temperature increases by
1 °C and maximally by 2 °C after 2 hours.
Actuating the SLEEP button (8) again deactivates this setting.
Dehumidification operation (drying)
The temperature cannot be regulated during
dehumidification operation, the fan speed is low.
In dehumidification (drying) mode humidity is extracted from
the air and collected in an internal tank.
Once the maximum filling level of the water tank is reached,
E4 or the ALARM warning light appears on the display.
Drain the water tank when it is full. See Emptying the
condensation tank on page 11.
Discharging the condensate
In dehumidification mode the rubber cap on the drain hole (1)
is to be removed and replaced by a proper drain pipe.
Remove the exhaust air hose, connect a drain pipe to the
drain hole (1) and drain the water to enhance the
dehumidification capacity.
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Trotec PAC 2000X at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Trotec PAC 2000X in the language / languages: English as an attachment in your email.

The manual is 1,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Trotec PAC 2000X

Trotec PAC 2000X User Manual - German - 18 pages

Trotec PAC 2000X User Manual - Dutch - 18 pages

Trotec PAC 2000X User Manual - French - 18 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info